5100g cable connection – IntraServer Technology ITIpci 5100G/GF User Manual

Page 22

Advertising
background image

LSI Logic Corporation

Page 22 of 56

5100G Cable Connection

The 5100G adapter has one RJ-45 connector used for attaching the server to
an Ethernet twisted pair copper segment. The port is auto-negotiating and
supports full-duplex operation.

1. Prepare an appropriate cable.

The following table lists cable characteristics required for connecting to
10/100/100 Base-T ports:

10/100/1000BASE-T Cable Specifications

Port Type

Connector

Media

Maximum

Distance

10Base-T RJ-45 Cat. 3, 4 or 5 UTP 100 Meters
100/1000Base-T RJ-45

Cat. 5 UTP

100 Meters

Table 7: 10/100/1000BASE-T Cable Specifications

2. Connect one end of the cable to the ITI-5100G/GF adapter.

3. Connect the other end of the cable to a Gigabit Ethernet network port.

Note: The adapter port LEDs are not functional (they will not reflect
port link or data status) until the adapter driver software is installed.