IBM 2104 Model DU3 User Manual

Page 59

Advertising
background image

One Adapter in Each of Two Using Systems Connected to Two
2104s (Model DU3)

1

SCSI interface card

2

For HACMP configurations in standby and mutual takeover mode:

v

PCI Dual-Channel Ultra2 SCSI Adapter (type 4-R, feature 6205)
The two adapters must not be in the same using system.

v

PCI Dual-Channel Ultra3 SCSI Adapter (type 4-Y, feature 6203)
The two adapters must not be in the same using system.

The adapters must be in two separate using systems.

For non-HACMP configurations, the connections can be to either two different using
systems or to the same using system, but disk drive modules must not be shared:

v

PCI Dual-Channel Ultra2 SCSI Adapter (type 4-R, feature 6205)

v

PCI Dual-Channel Ultra3 SCSI Adapter (type 4-Y, feature 6203)

v

Ultra2 SCSI Integrated port

Attention: This 2104 configuration is not supported on the Linux operating system.

Attention: The SCSI address of the adapter that is connected to the 2104 must be
different from the addresses of the installed disk drive modules. When a second
adapter is connected to a 2104, the SCSI address of that adapter must be different
from the address of the first adapter and the addresses of the disk drive modules
installed in the 2104.

In each 2104, slots 6 and 7 (SCSI addresses 5 and 6) must contain dummy disk
drive modules. Each 2104 can contain no more than 12 disk drive modules.

2104 Subsystem

1

1

1

1

2104 Subsystem

Using System

2

Using System

2

Maximum of 12

disk drive modules

Maximum of 12

disk drive modules

Figure 29. One Adapter in Each of Two Using Systems Connected to Two 2104s (Single-Bus
Mode)

Appendix A. Operating with RISC Systems

43

|

Advertising