One Adapter in Each of Two Non-HACMP Using Systems
Connected to One 2104 Model DU3

1

SCSI interface card

2

SCSI or SCSI RAID adapter of one of these types:

v

PCI SCSI-2 Single-Ended Fast/Wide Adapter (type 4-A, feature 6208)

v

PCI Single-Ended Ultra SCSI Adapter (type 4-K, feature 6206)

v

PCI Dual-Channel Ultra2 SCSI Adapter (type 4-R, feature 6205)

v

PCI Dual-Channel Ultra3 SCSI Adapter (type 4-Y, feature 6203)

v

PCI 3-Channel Ultra2 SCSI RAID Adapter (type 4-T feature 2494)

v

PCI 4-Channel Ultra3 SCSI RAID Adapter (type 4-X, feature 2498)

Note: Connection can be to an integrated SCSI port instead of to a SCSI connector
on one of the listed SCSI adapters

Attention: This 2104 configuration is supported on the Linux for pSeries operating
system when attached to the host with the PCI Dual-Channel Ultra3 SCSI Adapter
(type 4–Y, feature 6203).

Attention: The SCSI address of the adapter that is connected to the 2104 must be
different from the addresses of the installed disk drive modules. When a second
adapter is connected to a 2104, the SCSI address of that adapter must be different
from the address of the first adapter and the addresses of the installed disk drive
modules.

2104 Subsystem

1

1

Using System

2

Using System

2

Figure 36. One Adapter in Each of Two Non-HACMP Using Systems Connected to One 2104
Model DU3 (Dual-Bus Mode)

Appendix A. Operating with RISC Systems