3power management, 1 power measurement support, Rv p – Intel ATOM US15W User Manual

Page 21

Advertising
background image


Power Management

User’s Manual

21

Document Number: 320264

3

Power Management

3.1

Power Measurement Support

Power measurement resistors are provided to measure the power on many of the
subsystems.

Table 5. Power Measurement Resistor

Feature

Value

Tolerance 1%

Value 10

NOTE: Intel recommends that larger (~10 mΩ) resistors be stuffed for greater accuracy.

Power on a particular subsystem is calculated using the following formula:

Equation 1.

R

V

P

2

=

R = value of the sense resistor (typically 0.01 Ω)

V = the voltage difference measured across the sense resistor.

Use a high precision digital multi-meter tool such as the Agilent 34401A digital multi-
meter. Refer to

Table 6

for a comparison of a high-precision, digital multi-meter

(Agilent 34401A) versus a precision, digital multi-meter (Fluke 79).

Table 6. Digital Multi-Meter Comparison

Example System

Sense Resistor Value

0.01 Ω

Voltage Difference Across Resistor

1.492 mV (149.2 mA)

Calculated Power

0.223 mW