SPECIFICATIONS
All specifications are warranted unless noted typical and apply to the 61-320, 61-322 and 61-324.

Stated accuracies are at 23ºC ± 5ºC at less than 80% relative humidity and without the battery
indicator displayed.

General specifications

Characteristics

Description

Display count

6,000

Numeric update rate

1.5 times / sec

Polarity display

Automatic

Overrange display

“OL” is displayed

Low voltage indicator

is indicated

Automatic power-off time

Automatic backlight off = 10 minutes

Power source

1.5 x 2 IEC LR03 or AAA size for 61-320
One 9V dry cell battery for 61-322 and 61-324

Maximum input voltage

1000V CAT III between V and COM

Maximum floating voltage

1000V CAT III between any terminal and earth ground

Maximum input current

600mA between mA and COM

Maximum open circuit Voltage (current inputs)

600V between mA and COM

Overload protection mA connector

1A (600V) fast blow fuse

V connector

1100 Vp V , V , Ω,

,

,

, Hz, µA

Temperature Coefficient

0.15 x (Spec. Accuracy) / ºC, <18ºC or >28ºC

Battery Life

300 hours typical (alkaline)


Form number TM61320-2-4

Rev 2 September 2002

Advertising
This manual is related to the following products: