Creating an insteon scene – INSTEON SWITCHLINC 2476D User Manual

Page 15

Advertising
background image

INSTEON SwitchLinc V2 Dimmer User’s Guide

Unlinking a Controlled INSTEON Device from SwitchLinc Dimmer

If you are no longer going to use an INSTEON Device that has previously been linked to SwitchLinc
Dimmer, it is very important that you unlink it, because otherwise SwitchLinc Dimmer will retry any
commands intended for the unused INSTEON Device, thus slowing down your system.

1. Set SwitchLinc Dimmer to Linking Mode by pressing and holding the Paddle Top for 10 seconds

until the top LED in the LED Bar begins blinking slowly and the controlled light flashes.

2. Set SwitchLinc Dimmer to Unlinking Mode by pressing and holding the Paddle Top again for 10

seconds until the controlled light flashes again.

3. Follow the same method given above that you used to link your INSTEON Device to unlink it. On

most INSTEON Devices, you just push an ON Button for 10 seconds or a SET Button for 3 seconds.

4. Go back to the SwitchLinc Dimmer that you placed in Unlinking Mode. If linking was successful, the

top LED in its LED Bar will not be blinking but will remain steadily on.

Creating an INSTEON Scene

INSTEON Scenes let you activate dramatic lighting moods with the press of just one button. INSTEON
Scenes are very easy to set up – just link more than one INSTEON Device to SwitchLinc Dimmer. Then,
when you press either the Paddle Top or Paddle Bottom on SwitchLinc Dimmer, all of the INSTEON
Devices linked in the scene will respond as a group. You can link multiple INSTEON Devices to multiple
of INSTEON Controllers.

To add an additional INSTEON Device to a scene controlled by SwitchLinc Dimmer, simply follow the
same procedure as above in Linking SwitchLinc Dimmer to a Controlled INSTEON Device. To remove an
INSTEON Device from a scene, see Unlinking a Controlled INSTEON Device from SwitchLinc Dimmer.

TIP


You can avoid having to hold SwitchLinc Dimmer’s Paddle Top down for 10 seconds for each
INSTEON Device in a scene by placing SwitchLinc Dimmer in Scene Setup Mode, also called
Multilink Mode.

1. Set SwitchLinc Dimmer to Scene Setup Mode by

pressing and holding the Paddle Top for 10
seconds, then pressing the SET Button at the
bottom of the paddle. SwitchLinc Dimmer’s top
LED in the LED Bar will blink slowly.

2. Follow the linking method given above for the INSTEON Device you want to include in the scene.

On most INSTEON Devices, you just push an ON Button for 10 seconds or a SET Button for 3
seconds. SwitchLinc Dimmer will flash its controlled light to confirm linking, and the top LED in its
LED Bar will continue to blink slowly.

3. On some INSTEON Devices, you may be able to set up additional features, such as On-Levels or

Ramp Rates at this time.

4. Continue Steps 2 and 3 for any additional INSTEON Devices you want to link to the scene.

5. When you are finished linking INSTEON Devices to SwitchLinc Dimmer, complete Scene Setup by

pressing the Paddle Top (actually, any button press will terminate Scene Setup). The top LED in
SwitchLinc Dimmer’s LED Bar will stop blinking and remain steadily on. You have about 4
minutes of inactivity before SwitchLinc Dimmer’s Scene Setup Mode times out automatically.

Page 15 of 35