D remotely setting the ramp rate – INSTEON SWITCHLINC 2476D User Manual

Page 25

Advertising
background image

INSTEON SwitchLinc V2 Dimmer User’s Guide

3. Send an X10 ON or OFF command.

4. Send the following X10 Address sequence:

5. Send the X10 Scene Address (house code and unit code) that is to be removed.

6. SwitchLinc Dimmer will flash the light it is wired to and blink an LED in its LED Bar, indicating that the

X10 Scene Address has been removed.

Remotely Setting the Ramp Rate for an X10 Scene Address

The Ramp Rate of each module in each X10 Scene is adjustable. If this setting is not adjusted,
SwitchLinc Dimmer will use the Ramp Rate for its X10 Primary Address.

1. Using an X10 Controller, send the CLEAR Sequence:

2. Send SwitchLinc Dimmer's X10 Primary Address (house code and unit code).

3. Use any controller to adjust SwitchLinc Dimmer’s brightness so it corresponds to the Ramp Rate you

want in the table below. If you use SwitchLinc Dimmer’s paddle and you are careful, you can still set
one of 32 brightnesses even though there are only 9 LED brightness indicators. Brighter is faster.

4. Send the following X10 Address sequence:

O16

P16

M16

N16

O16

N16

M16

P16

M16

Bright-

ness

Level

Ramp

Rate in

Seconds

Bright-

ness

Level

Ramp

Rate in

Seconds

Bright-

ness

Level

Ramp

Rate in

Minutes

100%

0.1

65%

26

29%

2.5

97%

0.2

61%

28

26%

3.0

94%

0.3

58%

30

23%

3.5

90%

0.5

55%

32

19%

4.0

87%

2.0

52%

34

16%

4.5

84%

4.5

48%

38

13%

5

81%

6.5

45%

43

10%

6

77%

8.5

42%

47

6%

7

74%

19.0

39%

60

3%

8

71%

21.5

35%

90

0%

9

68%

23.5

32%

120

N16

O16

P16

M16

5. Send the X10 Scene Address (house code and unit code).

6. SwitchLinc Dimmer will flash the light it is wired to and blink an LED in its LED Bar, indicating that the

new Ramp Rate has been set for the X10 Scene Address.

Page 25 of 35

Advertising