Setting the ramp rate, Locking in a local on-level and ramp rate – INSTEON SWITCHLINC 2476D User Manual

Page 19

Advertising
background image

INSTEON SwitchLinc V2 Dimmer User’s Guide

Setting the Ramp Rate

The Ramp Rate sets the time it will take for the light you are controlling to go from OFF to the On-Level
brightness, or from the On-Level brightness to OFF. This time is adjustable from 0.1 to 9 seconds to
ramp between full-ON and full-OFF. The default is 0.1 second.

1. Hold down SwitchLinc Dimmer’s Paddle Top or Paddle Bottom to adjust the Ramp Rate of the

controlled light. Adjust the Ramp Rate to be faster by brightening the light, or adjust it to be slower by
dimming the light. The table below gives the approximate relationship between the brightness you
set and the Ramp Rate you get.

Approximate

Brightness

Level

Ramp

Rate in

Seconds

90-100%

0.1

77-87%

0.2

65-74%

0.3

52-61%

0.5

39-48%

2.0

26-35%

4.5

13-23%

6.5

1-10%

8.5

1%

9.0

NOTE


If the light is ramping to
less than full brightness,
then the time it will take
will be proportionately
less. For instance, if the
light is going to half
brightness, the time it will
take for a given Ramp
Rate will be halved.

2. Double-press the SET Button at the bottom of the paddle.

3. SwitchLinc Dimmer will flash the controlled light once to confirm the Ramp Rate setting.

BE CAREFUL


If you got two flashes of the light, you didn’t double-press the SET Button fast enough, and
SwitchLinc Dimmer incorrectly thought you set up the On-Level twice. Re-set the correct On-
Level and try the Ramp Rate setting again.

Locking In a Remote-Controlled On-Level and Ramp Rate

Whenever you link an INSTEON Controller to SwitchLinc Dimmer, the current On-Level and Ramp Rate
values are stored in SwitchLinc Dimmer’s memory. So, locking in a remote-controlled On-Level and
Ramp Rate is really just the same as linking. Just follow the instructions in the section Linking an
INSTEON Controller to SwitchLinc Dimmer
, above.

Linking an INSTEON Controller to SwitchLinc Dimmer restores the previous values for the Local On-Level
and Local Ramp Rate. So, linking does not affect the Local On-Level and Ramp Rate.

Locking In a Local On-Level and Ramp Rate

To lock in the current On-Level and Ramp Rate as the Local On-Level and Ramp Rate, all you have to do
is not link SwitchLinc Dimmer to an INSTEON Controller for four minutes. After the four-minute timeout,
the current On-Level and current Ramp Rate will be permanently locked in as the Local On-Level and
Local Ramp Rate.