Document scanner cleaning (Model TI8, TI9, TG8, TG9)

The scanner surface should be cleaned after 10 000 documents or every three
months or whenever image quality deteriorates.

1. Open the ribbon cover. See Figure 34.

2. Move the impact print head to its rightmost position, as shown.

3. Rotate the scanner registration plate 180° up to expose the glass scanner

surface. See Figure 34.

4. Use a cotton swab that is lightly soaked with alcohol to wipe any residue from

the scanner glass surface.

5. Gently return the scanner registration plate to its original position.

6. The scanner should be recalibrated after it has been cleaned. See “Document

scanner calibration (Models TI8, TI9, TG8, TG9)” on page 60.

Scanner
Surface

Registration Plate

Print Head

Ribbon Access Cover

Figure 34. Scanner and print head location (Model TI8, TI9, TG8, TG9)