Dos ndis 2 – IBM 16/4 Token-Ring User Manual

Page 29

Advertising
background image

1. If you are installing the NetWare Requester on a workstation, select Edit

CONFIG.SYS and Copy All Files.... If the NetWare Requester is already
installed on the workstation and only a driver update is needed, then select
Only Edit CONFIG.SYS....

2. On the next panel, specify the name of the adapter driver: IBMTRPO.SYS.

3. When you get to the panel labeled Copy ODI LAN Driver files, select Copy

only the default driver.

4. Follow the instructions on the panels to continue installation.

5. When Installation Complete appears in the Requester window, go to the

Configuration menu and select This workstation....

6. Select Edit to accept the default location for the NET.CFG file.

7. In the edit box titled Current NET.CFG File Contents, type the following lines:

link driver IBMTRPO

SLOT 10001

link support

BUFFERS 84096

Notes:

a. See “Appendix F. Novell NetWare DOS ODI driver parameters” on page 77

for a complete list of parameters that you can specify in the NET.CFG file.

b. To enable source routing, changes will have to be made to the

CONFIG.SYS file. Refer to Novell’s Workstation for OS/2 manual for
instructions on how to enable source routing.

c. The lines in the NetWare Requester section of the CONFIG.SYS file must

be in a certain order. Do not reorder the lines in this section of
CONFIG.SYS. Refer to the Novell manuals for more information.

8. Select Save to complete the NetWare Requester installation.

9. Reboot the computer to apply the changes.

Note: To make changes in the NetWare Requester configuration, double-click

the Novell icon on the desktop. Double-click the Install icon in the Novell
window. Go to the Configuration and select This workstation.... Make
sure that the correct NET.CFG is shown in the next dialog box and select
Edit. Edit the NET.CFG file in the edit box titled Current NET.CFG File
Contents. When the changes are complete, select Save and reboot the
computer to apply the changes.

10. Check for the following conditions to determine whether the adapter is working

correctly and whether installation has been completed successfully:
v The device driver files loaded successfully. There are no error messages.
v The adapter LEDs indicate normal operation: Green ON, Amber OFF.

If you experience problems, see “Chapter 4. Problem solving” on page 37.

DOS NDIS 2

Use the following procedure to install the DOS NDIS 2 device driver:

1. Insert the CD-ROM or the NDIS Drivers diskette into the appropriate drive.

2. Use your operating system documentation to install the driver (IBMTRP.DOS).

This driver is located in the \dos subdirectory on both diskette and the CD-ROM.

3. Modify the parameters, if needed. See “Appendix B. NDIS 2 device driver

parameters” on page 53.

Chapter 3. Software installation

21

Advertising