Intel confidential – Intel 537EX User Manual

Page 63

Advertising
background image

536EX Chipset Developer’s Manual

63

Intel Confidential

Error Correction and Data Compression

+ES=m

see ‘m’

Error Control Selection: The +ES=m command controls the operation of the V.42 error detection and
correction protocol in the DCE. Once a connection has been established between the DCE and DTE, the
<orig_rqst> subparameter can put the interface into synchronous access mode. In the default settings,
synchronous access mode is disabled. To change modes, send another +ES command.

m = <orig_rqst>, <orig_fbk>, <ans_fbk>
Defaults: m = 3, 0, 2

<orig_rqst> Specifies the initial requested mode of operation when the DCE is the originator. If
<orig_rqst>=6, the modem ignores the <orig_fbk> setting.

Range: 1–4, 6

0

Reserved.

1

Initiate call with buffered mode only.

2

Initiate V.42 without detection phase. If V.80 mode is in use, this is a request to disable V.42
detection phase.

3*

Initiate V.42 with detection phase.

4

Initiate alternate protocol.

6

Initiate synchronous access mode when connection is completed and when in data state.

<orig_fbk> Specifies the acceptable fallback mode of operation when the DCE is the originator. This
setting is ignored if <orig_rqst>=6.

Range: 0–2, 4

0*

Error control optional (either LAPM or alternative acceptable). If error control is not
established, maintain the DTE-DCE data rate and use the V.14 buffered mode with flow
control during non-error control operation.

1

Error control optional (either LAPM or alternative acceptable). If error control is not
established, change the DTE-DCE data rate to match the line rate and use direct mode.

2

Error control required (either LAPM or alternative acceptable). If error control is not
established, disconnect.

3

Reserved.

4

Error control required (only alternative protocol acceptable). If error control is not established,
disconnect.

<ans_fbk> Specifies the acceptable fallback mode of operation when the DCE is the answerer.

Range: 1, 2, 4–6, 8

0

Direct mode.

1

Error control disabled, use buffered mode.

2*

Error control optional (either LAPM or alternative acceptable). If error control is not
established, maintain the DTE-DCE data rate and use local buffering and flow control during
non-error control operation.

3

Reserved.

4

Error control is required (either LAPM or alternative is acceptable). If error control is not
established, disconnect.

5

Error control required (only LAPM acceptable). If error control is not established, disconnect.

6

Error control required (only the alternative protocol is acceptable). If error control is not
established, disconnect.

8

Initiate synchronous access mode when the connection is complete and data state is entered.

Table 21. V.44/V.42/V.42 bis and MNP Data Modem Command Descriptions (Continued)

Command

Default

Description

NOTE: An asterisk (*) denotes the factory-default setting.

+ES=1,0,1

Buffered mode

+ES=4,4,6

MNP reliable mode

+ES=3,0,2*

V.42 autoreliable mode

+ES=3,2,4

V.42 reliable mode

+ES=2,3,5

LAPM reliable mode

+ES=6, ,8

Synchronous access mode