5 rmon alarm: overview, Figure 78 rmon alarm: overview, Table 59 rmon alarm: overview – IronPort Systems ES-1528 User Manual

Page 126

Advertising
background image

Chapter 19 RMON-Lite

ES-1528 User’s Guide

126

19.5 RMON Alarm: Overview

Use the RMON Alarm: Overview screen to view configured alarms that occur when the
sampled data exceeds the specified threshold. To open this screen select [3] Alarm in the
RMON MIB Table: drop down list box in the RMON-Lite screen.

Figure 78 RMON Alarm: Overview.

The following table describes the labels in this screen.

Jabbers

This field displays the number of frames dropped in this polling sample because they

were longer than 1518 octets and contained an invalid FCS, including alignment

errors.

Collisions

This field displays the total number of collisions that occurred in this polling sample.

Utilization (%)

This field displays the utilization as a percentage of maximum utilization allowed on

the port in this polling sample.

History

Statistics

Overview

Click this to go back to the RMON History Statistics: Overview screen.

Table 58 RMON History Statistics: Control (continued)

LABEL

DESCRIPTION

Table 59 RMON Alarm: Overview

LABEL

DESCRIPTION

RMON MIB

Table:

Use this drop down list box to select the MIB table you want to view. Click Apply to

refresh the screen to the selected MIB table view.

Refresh

Click this to update all the fields in the RMON Alarm: Overview screen.

Create new

Alarm

Click this to view the RMON Alarm: Create New Alarm screen where you can

configure the parameters for an alarm.

Index

This field displays the alarm configuration index number. Click this number to edit the

alarm entry.

Interval (sec)

This field displays the time interval (in seconds) between data samplings.

Variable

This field displays the name of the MIB field whose data is to be sampled.

Sample Type

This field displays the method of obtaining the sample value (absoluteValue or

deltaValue).

Value

This field displays the value of the statistic during the last sampling period. This value

is for comparing against the RisingThreshold and FallingThreshold values.

Startup Alarm

This field displays the alarm type (1:rising, 2:falling, or 3:risingOrFallingAlarm)

that can be sent when this alarm is first activated.

Advertising