Quantum Series Installation and Service Manual

720901120

-

14 -

No concentrate dis-

pensed, water only

Dispense tube not fully

engaged into recepta-

cle on concentrate
pouch

Refer to Concentrate Loading sec-

tion of this manual

Dispense tube discon-

nected from mixing

chamber

Refer to Concentrate Loading sec-

tion of this manual

Slide block on pump in

open position

Close and lock the slide block.

Refer to Concentrate Loading
section of this manual

Switch on pump platform in

FLUSH position

Move switch to RUN position

Concentrate too cold, not

properly thawed

Concentrate should be 34

o

F -40

o

F

(1.1

o

C –4.5

o

C) prior to loading

Defective pump motor

Replace pump motor

Excessive remnant left

in empty concen-
trate pouch

Concentrate pouch improp-

erly thawed

Concentrate should be 34

o

F -40

o

F

(1.1

o

C –4.5

o

C) prior to loading

Concentrate pouch and/or

dispense tube improp-
erly installed

Refer to Concentrate Loading sec-

tion of this manual

Concentrate refill light

comes on prema-
turely

Concentrate pouch improp-

erly thawed

Concentrate should be 34

o

F -40

o

F

(1.1

o

C –4.5

o

C) prior to load-

ing.

Concentrate pouch and/or

dispense tube improp-
erly installed

Refer to concentrate loading sec-

tion of this manual

Loose wiring

Check wiring connections between

the pump motor and the VRB

board

Bad VRB board

Replace VRB board

Bad pump motor

Replace pump motor

Concentrate refill light

does not come on at
all

Pump improperly locked or

pump is open

Close and lock Pump

Run/flush switch is in the

FLUSH position

Move switch to the RUN position