Quantum Series Installation and Service Manual

720901120

-

16 -

Concentrate warm,

water cold (con’t)

Loss of refrigerant charge

due to leak in system

Repair leak and recharge system

Brix Problem

Water supply pressure too

low, less than 20 psi (1.4
bar) flowing or water
pressure fluctuates

sharply

Correct water supply problem to

ensure a constant 40 psi (3 bar)
flowing to the dispenser

Water flow control binding

or spring is defective

Clean and/or replace parts as nec-

essary

Improperly thawed concen-

trate. Brix changes as
the concentrate temper-
ature changes (concen-
trate becomes thinner
as temperature rises)

Concentrate should 34

o

F -40

o

F

(1.1

o

C –4.5

o

C) prior to loading

Check that the rollers on the

pump are spinning
freely with no tube in
place

If they are sticky or locked up see

platform removal and cleaning
procedure.

Pump Inoperative

Pump motor defective

28VDC should be present at pump

motor during dispense. If volt-
age is present and motor does
not start, replace pump motor

No power to transformer or

no 28VAC output from
transformer

Confirm transformer has line volt-

age present on primary side. If
no 28VAC output from the sec-
ondary replace transformer

Defective voltage regulator

board (VRB) located
inside front electrical
box

Measure across the blue and black

wire located in the upper left
corner of the board. There
should be 28VDC present when
the dispense button is pressed.
Replace VRB if necessary

Defective portion control

board

Disconnect wire harness from rear

of portion control, close door
switch and short the orange
and black wires together on the
harness. If unit dispenses por-

tion control board is defective. If
it does not dispense the voltage
regulator board is defective.