Concentrate loading and brixing – Cornelius QUANTUM SERIES User Manual

Page 7

Advertising
background image

Quantum Series Installation and Service Manual

- 5 -

720901120

CONCENTRATE

LOADING AND BRIXING

P

LACING

C

ONCENTRATE

P

RODUCTS

ON

D

ISPENSING

P

LATFORM

To engage the concentrate container, place it in the desired position and press down into bottle
adapter opening on dispensing platform tray (inside the cabinet).

NOTE: Make sure o-ring seal on the container adapter is lubricated; otherwise, you
may experience difficulties with container replacement.

NOTE: Concentrate in the containers must be completely thawed and be within the
temperature range of 35

°

F

-

40

°

F (1.6

°

C

- 4.4°

C). Failing to supply concentrate inside

the recommended temperature range, especially below 35

°

F (1.6

°

C), will cause an

out of brix drink.

It is recommended the concentrate be thawed in a refrigerated (35

°

F

-

40

°

F) (1.6

°

C

- 4.4°

C) com-

partment for 36 to 48 hours before use.

It is recommended that the thawed concentrate be thoroughly shaken before use.

C

HANGING

C

ONCENTRATE

F

LAVOR

1.

Perform flush cycle

2.

Move valve handle to “Dispense” position

3.

Replace concentrate container

P

UMP

P

RIMING

1.

Follow instructions in paragraph “Placing Concentrate Products on the Dispensing Platform”

2.

Close the door (or unit will not activate)

3.

Depress the push button until concentrate appears at the dispensing nozzle.

B

RIX

S

ETTING

1.

Make two (2) full clockwise turns of the corresponding brix knob from the “all the way out” po-
sition (factory set). These two turns will bring you within one turn of proper brix setting. (Refer
to brix table located on the inside of the refrigerated compartment door).

2.

Dispense 1/2 cup of juice and discard.

3.

Dispense 1/2 cup of juice and use refractometer to check brix level.

4.

Clockwise rotation of the knob decreases brix level for example from 13% to 11.5%. Counter-
clockwise will increase brix level for example from 11.5% to 13%.

If a brix problem is experienced, refer to troubleshooting guide.

Advertising