Adjustment procedures, Preparation, 1 preparation – Icom IC-F3061S User Manual

Page 13

Advertising
background image

SECTION 6

ADJUSTMENT PROCEDURES

▄ REQUIRED TEST EQUIPMENT

EQUIPMENT

GRADE AND RANGE

EQUIPMENT

GRADE AND RANGE

FM deviation meter

Frequency range
Measuring range

: DC–300 MHz
: 0 to

±10 kHz

Attenuator

Power attenuation
Capacity

: 20 or 30 dB
: 10 W

Frequency counter

Frequency range
Frequency accuracy
Sensitivity

: 0.1–300 MHz
: ±1 ppm or better
: 100 mV or better

Standard signal
generator (SSG)

Frequency range
Output level

: 0.1–300 MHz
: 0.1 µV to 32 mV

(–127 to –17 dBm)

RF power meter

Measuring range
Frequency range
Impedance
SWR

: 1–10 W
: 100–300 MHz
: 50

: Better than 1.2 : 1

Oscilloscope

Frequency rang
Measuring range

: DC–20 MHz
: 0.01–20 V

External speaker

Input impedance
Capacity

: 8

: 1 W or more

6 - 1

6-1 PREPARATION

When adjusting IC-F3060 series, the optional CS-F3060 ADJ

ADJUSTMENT SOFTWARE

(Rev. 1.1 or later), OPC-966

JIG CABLE

(modifi ed OPC-966

CLONING CABLE

; see illustration page 5-2) and below test equipments are required.

SYSTEM REQUIREMENTS

• Microsoft

®

Windows

®

98/98SE/Me/2000/XP

• RS-232C serial port (D-sub 9 pin)

▄ ADJUSTMENYT SOFTWARE INSTALLATION

q Quit all applications when Windows is running.

w Insert the CD into the appropriate CD drive.

e Double-click the “Setup.exe” contained in the ‘CS-F3060

ADJ’ folder in the CD drive.

r The “Welcome to the InstallShield Wizard for CS-F3060

ADJ” will appear. Click [Next>].

t The “Choose Destination Location” will appear. Then click

[Next>] to install the software to the destination folder. (e.g.
C:\Program Files\Icom\CS-F3060 ADJ)

y After the installation is completed, the “InstallShield Wiz-

ard Complete” will appear. Then click [Finish].

u Eject the CD.

i Program group ‘CS-F3060 ADJ’ appears in the ‘Programs’

folder of the start menu, and ‘CS-F3060 ADJ’ icon ap-
pears on the desk top screen.

▄ BEFORE STARTING SOFTWARE ADJUSTMENT

Clone the adjustment frequencies into the transceiver, and
set the confi guration using with the CS-F3060

CLONING SOFT-

WARE

before starting the software adjustment. Otherwise, the

software adjustment can not be started.

CAUTION!: BACK UP the originally programmed mem-

ory data in the transceiver before program-
ming the adjustment frequencies.
When program the adjustment frequencies into
the transceiver, the transceiver’s memory data
will be overwritten and lose original memory
data at the same time.

Microsoft and Windows are registered trademarks of Micro-
soft Corporation in the U.S.A. and other countries.

STARTING SOFTWARE ADJUSTMENT

q Connect the transceiver and PC with OPC-966

JIG CABLE

.

w Turn the transceiver power ON.

e Boot up Windows, and click the program group ‘CS-F3060

ADJ’ in the ‘Programs’ folder of the [Start] menu, then
CS-F3060 series ADJ’s window appears.

r Click ‘Connect’ on the CS-F3060 ADJ’s window, then

appears transceiver’s up-to-date condition.

t Set or modify adjustment data as specifi ed.

• ADJUSTMENT FREQUENCY LIST

CH

FREQUENCY

ADJUSTMENT ITEM

1

174.000 MHz

TX power
Mode

: Low1
: Narrow

2

154.900 MHz

TX power
Mode

: Low1
: Narrow

3

155.000 MHz

TX power
Mode

: High
: Wide

4

155.000 MHz

TX power
Mode

: Low2
: Wide

5

155.000 MHz

TX power
Mode

: Low1
: Wide

6

136.000 MHz

TX power
Mode

: Low1
: Wide

7

174.000 MHz

TX power
Mode

: Low1
: Wide

8

136.000 MHz

TX power
Mode

: Low1
: Narrow

9*

155.000 MHz

TX power
Mode

: Low1
: Digital

10*

136.000 MHz

TX power
Mode

: Low1
: Digital

11*

174.000 MHz

TX power
Mode

: Low1
: Digital

12

155.000 MHz

TX power
Mode
CTCSS

: Low1
: Wide
: 151.4 Hz

13

155.000 MHz

TX power
Mode

: Low1
: Narrow

14

155.000 MHz

TX power
Mode

: Low1
: Middle

15

136.000 MHz

TX power
Mode

: Low1
: Middle

16

174.000 MHz

TX power
Mode

: Low1
: Middle

*; Necessary only when the optional UT-119 is installed.

; [EUR-01] only

Advertising