Frequency adjustment, 2 frequency adjustment – Icom IC-F3061S User Manual

Page 52

Advertising
background image

6 - 4

5-2 FREQUENCY ADJUSTMENT

Select an adjustment item using [

↑] / [↓] keys, then set to the specifi ed value using [←] / [→] keys on the connected PC’s keyboard.

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

UNIT

OPERATION

PLL LOCK
VOLTAGE
[RX LVA1]

1 • Channel

• Lock voltage preset

[LV (RX1)]

• Receiving

: 1

: 51 [1.00 V]

PC

screen

Click [I/O Check] in the Clone
menu to open the “I/O Check
window.”
Click [Update (F5)] button, then
check the “LVIN” item on the
CS-F3060 ADJ’s screen as below.

1.00 V

[RX LVA2]

2 • Channel

• Lock voltage preset

[LV (RX2)]

• Receiving

: 2
: 51 [1.00 V]

[TX LVA]

3 • Channel

• Lock voltage preset
[LV (TX)]
• Transmitting

: 1

: 51 [1.00 V]

PLL LOCK
VOLTAGE

1 • Channel

• Receiving

: 4

PC

screen

Click [Update (F5)] button, then
check the “LVIN” item on the
CS-F3060 ADJ’s screen.

3.4–4.4 V

(Verify)

2 • Channel

• Receiving

: 3

3 • Channel

• Transmitting

: 3

REFERENCE
FREQUENCY
[REF]

• Channel

: 3

Top

panel

Loosely couple a frequency
counter to the antenna connec-
tor.

470.000000 MHz

(Low band)

520.000000 MHz

(High band)

• Connect an RF power meter to the

antenna connector.

• Transmitting

,OCK

• I/O Check window

Advertising