Power supply circuits, 4 power supply circuits (main unit), Pll circuit – Icom IC-F3061S User Manual

Page 47

Advertising
background image

Loop

filter

X1
15.3 MHz

Q2, D5, D6

RX VCO2

Q1, D1, D2

RX VCO1

TX VCO

Q3, D9, D10

PLL control signals from the CPU (IC18)

PLL unlock signal
to the CPU (IC18, pin 73)

15.3 MHz
reference frequency signal

• PLL CIRCUIT

Buffer
Q4

Buffer
Q6

Buffer
Q5

to transmitter circuit

to 1st mixer circuit

D15

D14

BPF

PLST

SSD

SCK

4

11

6

10

14

15

16

PLL IC (IC1)

Shift register

Prescaler

Phase

detector

Divide

ratio

adjustment

Charge

pump

Programmable

divider

Reference

divider

CPU5V

regurator

+5V

regurator

VREF

regurator

S5V

regurator

T5V

regurator

R5V

regurator

Power switch

Q30, Q31

Q12, Q13, Q8

IC9

IC6

Q14

Q15

Q16

HV

VCC

CPU5V

CPU

+5V

VREF

S5V

“S5C”

Voltage line

Control signal

8

28

26

27

“T5C”

“R5C”

T5V

Receiver circuits

Attached optional units,

AF amplifier controller

(FRONT UNIT; Q501, Q502, D508),

etc.

CPU (IC18),

EEPROM (IC19),

etc.

PLL IC (IC1),

Base band IC (IC5),

etc.

PLL IC (IC1)

Transmitter circuits

R5V

(IC18)

Attached optional units,

D/A converters,

etc.

Battery pack

The buffer-amplifi ed VCO output signals from the tunable BPF
(L601−L603, C601−C607) are applied to the PLL IC (IC1,
pin 6). The applied signals are divided at the prescaler and
programmable counter according to the “SSD” signal from the
CPU (IC18, pin 10). The divided signal is phase-compared with
the reference frequency signal from the reference frequency
oscillator (X1), at the phase detector.

The phase difference is output from pin 4 as a pulse type signal
after being passed through the internal charge pump. The output
signal is converted into the DC voltage (lock voltage) by passing
through the loop fi lter (R7, R8, R12, C14, C16, C19). The lock
voltage is applied to the varacter diodes (D1 and D2 of RX
VCO1, D5 and D6 of RX VCO2, D9 and D10 of TX VCO) and
locked to keep the VCO frequency constant.

If the oscillated signal drifts, its phase changes from that of
the reference frequency, causing a lock voltage change to
compensate for the drift in the VCO oscillating frequency.

5-4 POWER SUPPLY CIRCUITS (MAIN UNIT)

Voltage from the attached battery pack is routed to whole of the circuit in the transceiver via switches and regulators.

5 - 4

Advertising