6 - 6

5-4 RECEIVE ADJUSTMENT

Select an adjustment item using [

↑] / [↓] keys, then set to the specifi ed value using [←] / [→] keys on the connected PC’s keyboard.

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

UNIT

LOCATION

RECEIVE
SENSITIVITY
[BPF C ALL]

NOTE:

“RECEIVE SENSITIVITY” must be adjusted before “S-METER.” Otherwise, “S-METER” will not be

adjusted properly.

1

• Channel

: 1

Multi

connec-

tor

Connect the SINAD meter
with an 8

Ω load to the JIG

cable.

Minimum distortion

level

• Connect the SSG to the antenna connec-

tor and set as;

Frequency

Level
Modulation
Deviation
• Receiving

: 400 MHz (low band)
450 MHz (High band)
: +20 dBµ

(–87 dBm)

: 1 kHz
: ±3.5 kHz

S-METER
[RSSI]

1

• Channel

: 1

Push the [ENTER] key on the connected PC’s keyboard to set
“S3” level.

• Connect the SSG to the antenna connec-

tor and set as;

Frequency

Level
Modulation
Deviation
• Receiving

: 400 MHz (low band)
450 MHz (High band)
: +23 dBµ

(–84 dBm)

: 1 kHz
:

±3.5 kHz

2

• Set the SSG as;
Level
• Receiving

: –7dBµ

(–114 dBm)

Push the [ENTER] key on the connected PC’s keyboard to set
“S1” level.

SQUELCH
[SQL]

1 • Channel

: 1

External

speaker

Connect an 8

Ω speaker to

the JIG cable.

Set the [SQL] to the
value that the audio
signals just appears.

• Close the squelch by adjusting the value of
[SQL] item on the CS-F3060 ADJ’s screen.
• Connect the SSG to the antenna connec-

tor and set as;

Frequency

Level
Modulation
Deviation
• Receiving

: 400 MHz (low band)
450 MHz (High band)
: –14 dBµ

(–121 dBm)

: 1 kHz
:

±3.5 kHz

†;

The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.