IBM CP-X445 User Manual

Page 45

Advertising
background image

45

Lamp (continued)
When the indicators or a message prompts you to replace the lamp, replace the

lamp as soon as possible.

1.

Turn the projector off, and unplug the power cord. Allow the lamp to cool for

at least 45 minutes.

2.

To prepare a new lamp, contact your dealer and tell the lamp type number

=

DT00691. If the projector is mounted on the ceiling, or if the lamp has

broken, also ask the dealer to replace the lamp.

In the case of replacement by yourself,

3.

After making sure that the projector has

cooled adequately, slowly turn over the

projector, so that the bottom is facing up.

4.

Please unhook the claws of the lamp cover

and remove the lamp cover.

5.

Loosen the 2 screws (marked by arrow) of

the lamp, and slowly pick up the lamp by the

handles.

6.

Insert the new lamp, and retighten firmly two

screws that are loosened in the previous

process to lock it in place.

7.

Interlocking the 2 tabs of the lamp cover to

the projector, position the lamp cover on the

projector. Then push the center point of two

claws to fix the lamp cover.

8.

Slowly turn the projector so that the top is

facing up.

9.

Turn the projector on, and reset the lamp time

using the LAMP TIME function of OPTION

menu

(39)

.

NOTE • When the lamp has been replaced after the message of "THE

POWER WILL TURN OFF AFTER 0hr." is displayed, complete the following

operation within 10 minutes of switching power on.

• Incorrectly resetting of the lamp timer (resetting without replacement, or

neglect of resetting after replacement) will result in incorrect message functions.

Maintenance

Lamp cover

Screws marked

by arrow

Claws

Center point

of claws

Tabs

Claws