IBM CP-X445 User Manual

Page 51

Advertising
background image

51

Troubleshooting

Regarding the indicator lamps (continued)

POWER

indicator

LAMP

indicator

TEMP

indicator

Description

Blinking

In

Red

or

Lighting

In

Red

Turned

off

Blinking

In

Red

The cooling fan is not operating.

Please turn the power off, and allow the unit to cool

down at least 20 minutes. After the projector has

sufficiently cooled down, please make confirmation

that no foreign matter has become caught in the fan,

etc., and then turn the power on again.

If the same indication is displayed after the treatment,

please contact your dealer or service company.

Blinking

In

Red

or

Lighting

In

Red

Turned

off

Lighting

In

Red

There is a possibility that the interior portion

has become heated.

Please turn the power off, and allow the unit to cool

down at least 20 minutes. After the projector has

sufficiently cooled down, please make confirmation of

the following items, and then turn the power on again.

• Is there blockage of the air passage aperture?

• Is the air filter dirty?

• Does the peripheral temperature exceed 35°C?

If the same indication is displayed after the treatment,

please set the HIGH at the FAN SPEED of the item

SERVICE of the OPTION menu.

Lighting

In

Green

Alternative

blinking in

Red

There is a possibility that the interior portion

has become overcooled.

Please use the unit within the usage temperature

parameters (5°C to 35°C). After the treatment, resent

the power to ON.

Lighting

In

Green

Simultaneous

blinking in

Red

It is time to clean the air filter.

Please immediately turn the power OFF, and clean

or change the air filter by referring to the section “Air

Filter”. After cleaning or changed the air filter, please

be sure to reset the filter timer. After the treatment,

resent the power to ON.

NOTE • When the interior portion has become overheated, for safety

purposes, the power source is automatically turned off, and the indicator lamps

may also be turned off. In such a case, press the “” (OFF) side of the power

switch, and wait at least 45 minutes. After the projector has sufficiently cooled

down, please make confirmation of the attachment state of the lamp and lamp

cover, and then turn the power on again.

Advertising