About connection cables, Video signal cables, Dc 12 v or ac 24 v power supply cable – JVC TK-C215VP4U/E User Manual

Page 17: Video signal cables dc 12 v or ac 24 v, Power supply cable, A pg. 17)

Advertising
background image

17

The maximum connection distance varies with
the type of cable used. Please refer carefully to
the table for each cable during connection.

* Be sure to turn off the power of devices before

connecting cables.

Note:

● When mounting the heater (sold separately

part number KA-ZH215), make sure to
connect the power wire to an AC 24 V power
supply only.

Video signal cables

Connect the coaxial cables (BNC) to the video
signal output connector (BNC).

DC 12 V or AC 24 V power supply cable

Connect the DC 12 V or the AC 24 V power
supply to the DC 12 V/AC 24 V terminals on the
terminal board. To prevent connection errors or a
cable disconnection, we recommend the use of
lug plates for the connections. The following
table shows the connection distances and
connection cables provided that 2-conductor
VVF cables (vinyl-insulated vinyl sheath cables)
are used.

Note:

● If thin cables are used (i.e. with a high

resistance), a significant voltage drop will
occur when the unit is at its maximum power
consumption.
Either use a thick cable to restrict the voltage
drop at the camera side to below 10 %, or
place the power supply near to the camera.
When the voltage is low, the protection circuit
within the camera may be triggered and the
power of the camera may turn off
automatically.

● Do not allow input from both a DC 12 V and

AC 24 V power supply at the same time.

● When using a DC 12 V power supply, ensure

that the polarities of the cable are correct.

● The product shall be powered by Class 2

only.

● The AC 24 V power supply should conform to

the following:
U-type: Class 2 only
E-type: Isolated power supply only

About Connection Cables

Cable

Maximum extension (No cable compensator)

RG-59

200 m

RG-6

350 m

RG-11

450 m

To video Signal
Cable

To DC 12 V or AC 24 V
Power Supply

To Alarm Signal Cable
( TK-C215VP12U/E
Only)

Conductor diameter (mm)

R 1.0 mm
(AWG18)

R 1.6 mm
(AWG14)

R 2.0 mm
(AWG12)

TK-C215VP4U/E
Maximum
extension
(Without heater)

DC12V

50 m
(160ft)

140 m
(450ft)

220 m
(720ft)

AC24V

130 m
(420ft)

350 m
(1100ft)

550 m
(1800ft)

TK-C215VP4U/E
Maximum
extension
(With heater)

AC24V

40 m
(130 ft)

120 m
(390 ft)

180 m
(590 ft)

TK-C215VP12U/E
Maximum
extension
(Without heater)

DC12V

30 m
(100ft)

80 m
(260ft)

130 m
(430ft)

AC24V

80 m
(260ft)

210 m
(690ft)

340 m
(1120ft)

TK-C215VP12U/E
Maximum
extension
(With heater)

AC24V

30 m
(100 ft)

90 m
(300 ft)

140 m
(460 ft)

TK-C215VP4_JP.book Page 17 Thursday, November 2, 2006 10:51 AM