Alarm input/output terminal connection, Alarm input terminal, Alarm output terminal – JVC VN-V25U User Manual

Page 20: Alarm input/output terminal, Connection, Alarm input terminal alarm output terminal, Connection / installation, Caution, Input requirements, Output requirements

Advertising
background image

20

Connection / Installation

Connect the alarm input/output terminals with
external devices, such as a sensor or buzzer.
Plug/Unplug the cable while pressing the button
as shown in the diagram below.

Caution:

● Noises from an external source may cause

the camera to malfunction even when the
cable used is within 50 m. In this case, move
the cable away from the noise source.

Alarm Input Terminal

Connect this terminal to sensor devices, such as
an infrared sensor, door sensor, metal sensor or
manual switch.

Input requirements

● No-voltage relay NPN open collector input

● Polarity of input detection can be selected

using a software

● Make/Break (500 ms and above)

● Circuit current at low level: 1 mA

● Applied voltage at high level: 3.3 V

Alarm Output Terminal

Connect this terminal to annunciating devices,
such as annunciators, indicators, lights, or
buzzers.

Output requirements

● Equivalent to NPN open collector output (Set

the output logic using the Internet Explorer)

● Allowable applied voltage: DC12 V and below

● Allowable inflow current: 50 mA

● Momentary (100 ms - 5000 ms) output

(Set time using the Internet Explorer)

Caution:

● Connect the G terminal of this camera to the

GND terminal of the annunciating device or
alarm input sensor.

Alarm Input/Output Terminal
Connection

Cable to use

● Shielded cable

● Length of 50 m or shorter

CAUTION

: NEVER USE

PoE

AND

AC 24V

AT THE SAME TIME

DO NOT CONNECT TO THE TELEPHONE NETWORK

SEE INSTRUCTION MANUAL

CLASS

2

O

NL

Y

FOR

USA

ISOLA

TED

PO

W

ER

ONL

Y

FOR

EUR

OPE

AND

O

THER

MONITOR

OUT

10BASE-T/

100BASE-TX

PUSH

OUTPUT

ALARM

INPUT

2

AC24V

1

Po

E

G

2

1

2

1

Push

DC3.3 V

R

3.3 V

1 mA

VCC

OUT

GND

GND

OUT

R

(Alarm Input Equivalent Circuit)

G Terminal

INPUT 1 or
2 Terminal

Sensor Example

(1)

Sensor Example

(2)

Relay Switch, etc.

VN-V25U/26U

IN

R

DC 12 V

GND

Annunciating

Device Example

VN-V25U/26U

G Terminal

OUTPUT 1
or 2 Terminal

(Alarm Output Equivalent Circuit)

VN-V25U_26U_EN.book Page 20 Monday, January 21, 2008 10:13 AM

Advertising
This manual is related to the following products: