Horizontal Venting

(Horizontal Termination)

•

The maximum horizontal run made directly off
the rear of the stove into a standard horizontal
cap (#984 or #985) must be no more than a 9”
section of Simpson Dura-vent (#907B). See Figure
12-1.

•

The maximum horizontal run made directly off
the rear of the stove into a 14” snorkel cap (#982)
must be no more than a 24” section of Simpson
Dura-vent (#904). See Figure12-3.

•

The horizontal termination cap must maintain a
3" clearance (80 mm) to any overhead combus-
tible projections 2 1/2" (60 mm) or less. Maintain
12" (300 mm) clearance from projections exceed-
ing 2 1/2". See Figure 13.

•

Any horizontal run of vent must be level or have a
1/4" (5 mm) rise for every foot (300 mm) of run
toward the termination cap. DO NOT ALLOW THE
VENT TO RUN DOWNWARD, AS THIS CAN CAUSE
HIGH TEMPERATURES AND THE POSSIBILITY OF A
FIRE.

•

A 1” (26 mm) clearance must be maintained
around all co-axial vent pipe.

•

For buildings with vinyl siding, a Vinyl Siding
Standoff should be installed between the vent
cap and the exterior wall (Simpson Dura-Vent
#950). The Standoff prevents exposure of the
vinyl siding to excessive heat that can damage
the siding material.

•

A 10" X 10" (250 mm x 250 mm) square hole is
required to maintain proper vent clearances
through a combustible wall. Simpson Dura-Vent
Wall Thimble #942 installed according to the
manufacturer’s instructions meets clearance
requirements.

•

DO NOT FILL AIR SPACE WITH ANY TYPE OF
INSULATION.

•

Do not recess the termination cap into the
exterior wall or siding.

IMPORTANT:

FOLLOW THE INSTALLATION IN-

STRUCTIONS PROVIDED WITH EACH

SIMPSON DURA-VENT COMPONENT.

5” Max.

130 mm

Simpson Dura-Vent

Horizontal Termination

Cap #984 or #985

6” (150 mm) Min. Horizontal

Simpson Dura-Vent #908B

No Draft Restriction Required

OPTION # 2

Figure 12-2. Minimum horizontal run to rear
termination.

10” Max.

250 mm

Simpson Dura-Vent

Horizontal Termination

Cap #984 or #985

9” (230 mm) Max. Horizontal

Simpson Dura-Vent #907B

No Draft Restriction Required

OPTION # 1

Figure 12-1. Maximum horizontal run to rear
termination.

24” (610 mm) Max. Horizontal Run

into 14” Snorkel,

Simpson Dura-Vent #904

Both Draft Restrictors Required

Simpson Dura-Vent

14” Snorkel

Termination #982

OPTION # 3

Figure 12-3. Maximum horizontal run to a snorkel
termination.