Clearance to combustibles, Minimum stove clearance, Minimum vent pipe clearance – Jotul GF 200 DV User Manual

Page 7

Advertising
background image

7

Clearance to Combustibles

Minimum Stove Clearance

Rear

0”

(0mm)

Ceiling

17”

(432mm)

Corner

2”

(51mm)

Right Side

2”

(51mm)

Left Side

*10”

(255mm)

* Necessary for complete access to pull out required Lighting
Instructions Plate.

Minimum Vent Pipe Clearance

Horizontal runs:

Off the top of the pipe -

2” (26mm)

Off the sides and bottom -

1” (26mm)

Vertical runs:

All sides

-

1” (26mm)

See Figures 4 and 5.

Parallel Installation

Corner Installation

Mantel and Trim Clearances

Alcove Installation

Maximum Depth:

24” (610mm)

Minimum Width:

35” (890mm)

Minimum Ceiling Height:

42” (1067mm)

Figure 5. Clearance to rear corners.

Figure 3. Mantel / Trim Clearances

2”

51mm

2”

51mm

24”or greater depth

or ceiling

12” or less

6” or

less

1” deep

trim

must be

2” off

the top of

the

stove.

6”

153 mm

2”

51 mm

10”

255 mm

17”

432 mm

Figure 4. Clearances with stove parallel to the walls

* Allow 10” on left side of the appliance

for complete access to the lighting

instructions and control valve.

Rear Wall Clearance: 0” (ZERO mm)

Left Side*

10”

230 mm

Max.

Alcove

Depth

24”

610

mm

Right

Side

2”

25

mm