Tools Required:

• 1/4” Nut driver
• 7/16” and 1/2” open end wrench
• Torx T-20 or slotted screwdriver.

Fuel Conversion Kit Contents:

• 1 regulator tower labeled for Propane
• 3 regulator tower screws
• 1 burner orifice (#48 for NG, 3/64 for LPG)
• 1 pilot orifice (#51 for NG, #30 for LPG)
• Label A - to be completed and applied to the back
of the stove.
• Label B - to be applied to the stove Rating Plate.
• Small valve label - apply to the Control Valve body.

Conversion instructions are also included in the
conversion kit.

Mobile Home Installation

The Jøtul GF 200 DV Lillehamme can be installed for
use in a mobile home in the U.S. and Canada pro-
vided:
1. The stove is secured to the floor of the mobile

home. Use Jøtul Floor Mounting Kit #154342.

2. The stove is installed in accordance with Title 24

CFR, Part 3280- Manufactured Home Construction
and Safety Standard, in the U.S. Comply with CSA
Z240.4, Gas Equipped Recreational Vehicles and
Mobile Housing, in Canada.

3. Always contact your local building code officials

about installation restrictions and specific require-
ments in your area.

THIS APPLIANCE MAY BE INSTALLED AS

AN OEM INSTALLATION IN A MANUFAC-

TURED (MOBILE) HOME AND MUST BE

INSTALLED IN ACCORDANCE WITH THE

MAUFACTURER’S INSTRUCTIONS AND THE

MANUFACTURED HOME CONSTRUCTION

AND SAFETY STANDARD, TITLE 24 CFR,

PART 3280. THIS APPLIANCE IS ONLY FOR

USE WITH THE TYPE OF GAS THAT IS

INDICATED ON THE STOVE’S RATING

PLATE. A GAS CONVERSION KIT IS PRO-

VIDED WITH THE LILLEHAMMER DIRECT

VENT GAS STOVE.

THIS APPLIANCE MAY BE INSTALLED IN AN

AFTERMARKET PERMANENTLY LOCATED,

MANUFACTURED (MOBILE) HOME, WHERE

NOT PROHIBITED BY LOCAL CODES.

CET APPAREIL PEUT ETRE INSTALLE DANS

UN MAISON PREFABRIQUEE (MOBILE)

DEJA INSTALLEE A DEMEURE SI LES

REGLEMENTS LOCAUX LE PERMETTENT.

CET APPAREIL DOIT ETRE UTILISE

UNIQUEMENT AVEC LES TYPES DE GAS

INDIQUES SUR LA PLAQUE SIGNALETIQUE.

NE PAS L’UTILISER AVEC D’AUTRES GAS

SAUF SI UN KITDE CONVERSION CERTIFIE

EST INSTALLE.

Gas Conversion

The Jøtul GF 200 DV Lillehammer gas stove is
shipped from the factory equipped to burn NATU-
RAL GAS. Install the Fuel Conversion Kit, included
with the stove, if Propane use is necessary. The kit
contains all the necessary components needed for
safe conversion and includes appropriate conversion
notice labels.

WARNING:

THE CONVERSION KIT IS TO BE IN-

STALLED BY AN AUTHORIZED JØTUL

SERVICE TECHNICIAN IN ACCORDANCE

WITH THE MANUFACTURER’S INSTRUC-

TION AND ALL CODES AND REQUIRE-

MENTS OF THE AUTHORITY HAVING

JURISDICTION. FAILURE TO FOLLOW

THESE INSTRUCTIONS COULD RESULT

IN SERIOUS INJURY OR PROPERTY

DAMAGE. THE QUALIFIED AGENCY

PERFORMING THIS WORK ASSUMES

RESPONSIBILTY FOR THIS CONVER-

SION.

Canadian Requirements

THE CONVERSION SHALL BE CARRIED OUT

IN ACCORDANCE WITH THE REQUIREMENTS

OF THE PROVINCIAL AUTHORITIES HAVING

JURISDICTION AND IN ACCORDANCE WITH

THE REQUIREMENTS OF THE CAN1-B149.1

AND .2 INSTALLATION CODE.