CV-M77
6.8 Timing diagram for Long Time Exposure mode
1H=50.8
µ
s
1H Max
4H
1V x N (2VD Min)
Exposure time
770H
17H
9H
EXT HD
EXT VDINT VD
EEN
WEN
Video out
Remarks:1VD indicates 792H.The interval of EXT VD input has to be multiple number of 1VD.EEN is lov
INT VD
- 15 -