Receiving data (camera->pc), Cv-m77 – JAI CV-M77 User Manual

Page 17

Advertising
background image

CV-M77

C - Gain and analogue signals settings.

1 AGC switch

AS=[Param.]<CR><LF>
AS?<CR><LF>

0=OFF (Manual), 1=ON (Auto)

2 Master gain level

GA=[Param.]<CR><LF>
GA?<CR><LF>

0-700 Available

when

AS=0.

3 Red gain level

RG=[Param.]<CR><LF>
RG?<CR><LF>

0-255 Available

when

WB=0.

4 Blue gain level

BG=[Param.]<CR><LF>
BG?<CR><LF>

0-255 Available

when

WB=0.

5 AGC level

AG=[Param.]<CR><LF>
AG?<CR><LF>

0-255 Available

when

AS=1.

6 White balance

WB=[Param.]<CR><LF>
WB?<CR><LF>

0=Manual (Variable)
1=Auto (Variable)
2=4600K (Fixed)
3=5600K (Fixed)

Sets manual gain values
(RG, BG) when changed
to 0 from other selections.

7 Auto white balance

AW=[Param.]<CR><LF>

0=One push auto white balance

Available when WB=1.

8 Master setup level

SU=[Param.]<CR><LF>
SU?<CR><LF>

33-223

(default = 128)

9 Red setup level

RS=[Param.]<CR><LF>
RS?<CR><LF>

96-160

(default = 128)

10 Blue setup level

BS=[Param.]<CR><LF>
BS?<CR><LF>

96-160

(default = 128)

11 White clip level

WC=[Param.]<CR><LF>
WC?<CR><LF>

0-1023

12 Gamma select

GS=[Param.]<CR><LF>
GS?<CR><LF>

0=1, 1=0.45, 2=0.6

D - saving and loading data in EEPROM

1

Load settings
(from camera
EEPROM)

LD=[Param.]<CR><LF>

0=FACTORY DATA AREA
1=USER DATA AREA

2

Save settings
(to camera EEPROM)

SA=[Param.]<CR><LF>

1=USER DATA AREA

Latest used DATA AREA
becomes default at next
power up.

3

Save settings into
Factory Area.

SA00=[Param.]<CR><LF> 0=FACTORY DATA AREA

Not disclosed for user.

4

EEPROM Current
Area No. Request

EA?<CR><LF>

0=FACTORY DATA AREA
1=USER DATA AREA



7.3.1 Receiving Data (Camera->PC)


If the function succeeds, the return value is a handle to the newly allocated memory object. If the
setting succeeds, returned is the below word from the camera.

COMPLETE<CR><LF>


Error Messages:

Command Error:
01 Unknown Command!!<CR><LF>

Parameter Error:
02 Bad Parameters!!<CR><LF>



Response to Request Command
Example:

Request Command (PC→Camera)

Command Name

Format

Receiving Data(Camera→PC)

Remarks

Trigger Mode

TR?<CR><LF>

TR=[Param.]<CR><LF>

"Param." is same as

setting command.

- 17 -