Process settings screen (continued), Settings (continued) – JVC KY-F75 User Manual

Page 40

Advertising
background image

E36

4. Settings (continued)

Contents

Used to reduce noise in the video signal.
LOW/MIDDLE/HIGH :

Noise reduction is performed.

Amount of reduction is increased in the order of LOW

Ǟ

MIDDLE

Ǟ HIGH.

OFF:

Noise reduction is not performed.

Used to set whether the gamma curve to determine the
reproduction of black is to be the standard value or
customised.
NORMAL:

the gamma curve is set using the standard

value (0.45)

ADJUST:

set when changing the gamma curve

The gamma curve can be adjusted only when gamma is
set to ADJUST.
Increase the number:

Improves the gradation of bright
areas. However, the gradation of
black becomes poorer.

Decrease the number: Improves the gradation of black

areas. However, the gradation of
bright areas becomes poorer.

Selects whether the camera image should be negative
signal.
ON: Conversion to negative signal is made.
OFF: Conversion to negative signal is not made.

Selects whether DSP (Digital Signal Processing) should
be bypassed.
NORMAL: Not bypassed.
BYPASS: Bypassed. In this case the following setting

items are fixed as indicated and cannot be set.
• Detail:

OFF

• Level dep.:

– – –

• Noise sup.:

OFF

• Gamma:

1.00

• Nega:

OFF

• Pixel comp.: OFF
• Color matrix: OFF

Set Value

LOW

MIDDLE

HIGH

[OFF]

[NORMAL]

ADJUST

0.35

:

(0.01 step)

[0.45]

:

(0.05 step)

:

0.90
1.00

ON

[OFF]

[NORMAL]

BYPASS

Item

Noise sup.

Gamma

Level
When
“ADJUST” is
selected.

Nega

DSP bypass

MEMO

Note that details in fine sections of the image may get lost
as the noise reduction amount is increased.

Process settings screen (continued)