background image

Chapter 3---Electrical

3-10

Model 250 Service Manual

Figure 3-4

High Voltage Power Supply I/O signals.

HVPS - Inputs

HVPS_SYNC - this signal is generated on the Raster Timing Generator PCB.
Square wave HCT level with 50 or 33% duty cycle. The signal is synchronized to
horizontal sync.

/HV_ENA - The HVPS shutdown signal from the Video Amplifier PCB
(/VA_OK).

H_PARABOLA - The horizontal parabola from the Convergence Deflection PCB
used by the Dynamic Focus Amplifier.

V_PARABOLA - The vertical parabola from the Convergence Deflection PCB
used by the Dynamic Focus Amplifier.

± 15 V. - The power source for the analog circuitry in the High Voltage Power
Supply.

+ 80 V. - The input power for the High Voltage section of the High Voltage
Power Supply.

HVPS - Outputs

G1 Supply - goes to Video Amplifier PCB

G2 Supply - goes to Video Amplifier PCB

/HV_OK - goes to System Controller PCB