Arc lamp, 1 arc lamp – JVC 250 User Manual

Page 35

Advertising
background image

Chapter 4---Optical

4-2

Model 250 Service Manual

4.1 Arc

Lamp

The Arc Lamp is the beginning of the high intensity Light Path. It is located
inside a housing on the right side of the Optical Support Assembly (see Figure
4-5
).

Arc Lamp - Main Functions:

The Arc Lamp is a single component composed of a Xenon gas bulb at the center
of a compound elliptical reflector. It supplies the high intensity white light used
by the projector to put a very bright image on the screen. The expected 50% life
(half of initial light output) of an Arc Lamp is approximately 1000 hours.

Arc Lamp - Inputs

!

32 kV pulse to light the Arc Lamp Power Supply

!

2 kW constant power during normal operation

Arc Lamp - Operation

The Arc Lamp Power Supply and the Igniter Assembly work together to produce
a 32 kV pulse that ignites the Arc Lamp. After the Arc Lamp lights, the voltage
from the Arc Lamp Power Supply drops to a constant 25-31 volts at 70-85 amps.
It will stay at this level during normal Arc Lamp operation.

Arc Lamp - Service Adjustments

When a new Arc Lamp is installed, it will need to be aligned using the Arc Lamp
adjustment fixture located inside the Arc Lamp housing (see Figure 4-2).

Arc Lamp Adjustment

Tools Needed

Large Flatblade screwdriver

4-mm Hex-head wrench

Equipment Needed

Minolta Illumination Meter T-1 or equivalent

To align the Arc Lamp:

1.

Remove the front cover (see Section 6.1).

2.

Loosen the spider lock down bolt (see Figure 4-4).

3.

Power the projector ON and let it run for 15 minutes to stabilize.

4.

Verify that the "Shutters on Hide" box is checked in the System-
Preferences menu, then use the RGB key and the HIDE key to hide Red
and Blue. This prevents light coming from the Red and Blue ILA

®

s.

5.

Open the fan door of the Arc Lamp Enclosure housing using the large
Flatblade screwdriver to rotate the retaining screws 90

°

This gains access

to the three Arc Lamp alignment screws. The Arc Lamp fan disconnects
when this door is opened.

Advertising