24

SECTION 5: SERVICE PROCEDURES

RINSE REGULATING THERMOSTAT REPLACEMENT

5. Attach the jumper wires to the wires that you removed from
the old thermostat.

6. Slide the new imperial brass fitting from your kit onto the
new thermostat.

200 Series Technical Manual
7610-100-45-00 Rev. E (02/10/2006)

Removing the imperial brass fitting.

Attaching the jumper wires.

Sliding imperial fitting onto new thermostat.

Pulling the thermostat probe and fitting from the well.

Removing the wires from the thermostat.

Putting the new thermostat in the well.