Operating capacities – Jackson 200LT User Manual

Page 7

Advertising
background image

200 Series Technical Manual
7610-100-45-00 Rev. E (02/10/2006)

SECTION 1: SPECIFICATION INFORMATION

OPERATING CAPACITIES

PERFORMANCE/CAPABILITIES

OPERATING CAPACITY (RACKS/HOUR)

RACKS PER HOUR

57

DISHES PER HOUR

1425

GLASSES PER HOUR

1425

OPERATING CYCLE (SECONDS)

WASH TIME

45

RINSE TIME

11

TOTAL CYCLE

58

TANK CAPACITY (GALLONS)

WASH TANK (MINIMUM)

8.0

BOOSTER TANK

3.0

WASH PUMP CAPACITY

GALLONS PER MINUTE

150

TEMPERATURES

WASH---°F (MINIMUM)

150

RINSE---°F (MINIMUM)

180

WASH---°F (MINIMUM) (200 LT)

130

RINSE---°F (MINIMUM) (200 LT)

130

NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided on
this page is for reference only and may be subject to
change without notice.

STEAM REQUIREMENTS

COIL SIZE

3/4”

STEAM FLOW PRESSURE (P.S.I.)

10-20

CONSUMPTION @ 15 P.S.I. (LBS/HR)

45

WATER REQUIREMENTS (MINIMUM)

INLET TEMPERATURE (200)

180°F

INLET TEMPERATURE (200B)(40° Rise) 140°F
INLET TEMPERATURE (200B)(70° Rise)

110°F

INLET TEMPERATURE (200LT)

140°F

INLET TEMPERATURE (200S)

110°F

GALLONS PER HOUR

52.2

GALLONS PER RACK

0.92

WATER LINE SIZE NPT

3/4”

DRAIN LINE SIZE NPT

1 1/2”

FLOW PRESSURE P.S.I. (Optimum)

20

A5

MINIMUM CHLORINE REQUIRED (PPM)(200LT)

50

ELECTRICAL REQUIREMENTS

WASH PUMP MOTOR HP

1

NOTE: Typical Electrical Circuit is based upon (1) 125% of
the full amperage load of the machine and (2) typical fixed-
trip circuit breaker sizes as listed in the NEC 2002 Edition.
Local codes may require more stringent protection than
what is displayed here. Always verify with your electrical
service contractor that your circuit protection is adequate
and meets all applicable national and local codes. These
numbers are provided in this manual simply for reference
and may change without notice at any given time.

RINSE TYPICAL
HEATER TOTAL ELECTRICAL

MODEL

VOLTS PH HZ

RATINGS

AMPS

CIRCUIT

200B

208

1 60 12KW@230 72 A 90 AMP

200B

230

1 60 12KW@230 79 A 100 AMP

200B

208

3 60 12KW@230 40 A 50 AMP

200B

230

3 60 12KW@230 44 A 60 AMP

200B

460

3 60 12KW@230 22 A 25 AMP

200B

208

1 60 14KW@230 79 A 100 AMP

200B

230

1 60 14KW@230 87 A 110 AMP

200B

208

3 60 14KW@230 44 A 60 AMP

200B

230

3 60 14KW@230 49 A 70 AMP

200B

460

3 60 14KW@230 25 A 36 AMP

200

208

1 60 N/A

29 A 40 AMP

200

230

1 60 N/A

31 A 40 AMP

200

208

3 60 N/A

15 A 20 AMP

200

230

3 60 N/A

16 A 20 AMP

200

460

3 60 N/A

8 A 15 AMP

200/LT

208

1 60 N/A

29 A 40 AMP

200/LT

230

1 60 N/A

31 A 40 AMP

200/LT

208

3 60 N/A

15 A 20 AMP

200/LT

230

3 60 N/A

16 A 20 AMP

200/LT

460

3 60 N/A

8 A 15 AMP

200S

208

1 60 N/A

7 A 15 AMP

200S

230

1 60 N/A

7 A 15 AMP

200S

208

3 60 N/A

4 A 15 AMP

200S

230

3 60 N/A

4 A 15 AMP

200S

460

3 60 N/A

4 A 15 AMP

2

Advertising
This manual is related to the following products: