ENGINE:
The engine for this generator is governed to operate at

speeds close to 3600 RPM (60Hz) throughout the op-

erating load range. The no load speed (before a load is

applied) will be just a bit higher than the load speed and is

normally set to 3750 RPM.

WARNING: DO NOT TAMPER WITH THE

GOVERNOR MECHANISM, CHANGE THE

SETTING EXPERIMENTALLY, OR PUSH

THE THROTTLE OPEN IN AN ATTEMPT TO

GENERATE MORE ELECTRICAL CURRENT;

EQUIPMENT DAMAGE OR PERSONAL INJURY

MAY RESULT.

GOVERNOR SPEED ADJUSTMENT SHOULD

BE MADE ONLY BY A JOHN DEERE

CUSTOMER SERVICE REPRESENTATIVE.

CHANGING ENGINE OIL:
Change oil after initial 50 hours. Thereafter it should be

changed every 200 hours of operation.
Drain as follows:
1. Make sure the engine is level.
2. Start the engine and bring it up to operating

temperature.

3. Stop the engine.
4. Remove the oil cap/dipstick to allow the engine oil to

drain more easily.

5. Position a container under the engine to collect waste

oil.

6. Remove the drain plug located on the bottom of the

cylinder block. Allow oil to drain.

7. After all oil has been drained from the engine, install the

drain plug and tighten to 14-17 ft lbs.

8. Dispose of used oil properly.

TO FILL WITH OIL:
1. Make sure engine is level.
2. Remove oil cap/dipstick.
3. Add indicated amount of engine oil at either one of the

engine oil filler ports.

4. Wait one minute and check oil level.
5. Add more oil if necessary.
6. Fully reinsert oil cap/dipstick and hand tighten. Over-

tightening the oil cap/dipstick will damage it.

CAUTION: OIL BEING DRAINED MAY BE HOT.

TO REDUCE THE RISK OF BURN INJURY,

HANDLE WITH CARE. DISPOSE OF USED OIL

PROPERLY.

Service