Pump option), J-200 – Jacuzzi J - 200 J - 280 User Manual

Page 45

Advertising
background image

J-200

14.6 panel Flashes Fl1 or Fl2 (spas without Circulation pump

option)

A flashing “FL1” display means the pressure switch is

not closed when the jets pump 1 is activated. Proper

water flow is inhibited or the pressure switch has

malfunctioned. A flashing “FL2” display means the

pressure switch is malfunctioning closed. In either case,

the heater is deactivated. To correct condition, perform to the following:

Verify water level is one inch below lowest pillow. Add water if

1.

necessary.

Check for clogged or dirty filter cartridge (Sec. 12.1, page

2.

32).

Purge “air lock” from jets pump 1 by loosening the upper pump head

3.

drain screw (Figure A, page 17) for a few seconds to release trapped

air, then retighten drain screw. FINGER TIGHT ONLY!

If problem persists, contact your authorized Jacuzzi dealer.

4.

14.7 panel Flashes Fl1 or Fl2 (spas with Circulation pump

option)

A flashing “FL1” display means the flow switch is

malfunctioning open, the filter cartridge is excessively

dirty or an “air lock” condition has occurred at the

circulation pump intake. A flashing “FL2” display means

the flow switch is malfunctioning closed. In either case,

the spa heater will deactivate and jets pump #1 may also deactivate. To

correct condition perform the following:

Verify water level is 1" below lowest pillow. Add water if necessary.

1.

Check for clogged or dirty filter cartridge (Sec. 12.1, page

2.

32).

Purge “air lock” from circulation pump intake by removing filter

3.

cartridge. Hold your garden hose over the filter cartridge wall fitting

while using a rag as a seal around hose end. Ask a helper to turn

on water for 30 seconds, then turn off. Reinstall filter cartridge and

check spa (Sec. 12.1, page 32).

If the circulation pump is not running, turn power off at the main

4.

breaker, then turn power back on. This will reset the circulation pump

priming cycle. Once the pump is primed, the error should clear.

If problem persists, contact your authorized Jacuzzi dealer.

5.

41