Page 16 operation, 4 partial scan mode, 5 integration – JAI TM-6710 User Manual

Page 22: Internal slow reset mode, Figure 12

Advertising
background image

Page 16
Operation

TM-6710/6710CL High-Speed Progressive Scanning CCD Camera

FIGURE 12.

Internal Slow Reset Mode

3.3.4 Partial Scan Mode

A key advantage of the TM-6710 is the partial scan mode, which provides up to 300Hz frame rate
output. 200 line partial scan is output at 236Hz. 100 line partial scan is output at 300Hz.

3.3.5 Integration

Integration is activated by keeping INTEG control as active low. Integ is #11 of the 12-pin connector for
the TM-6710, (TTL) and #10 and 23 of the Camera Link connector for the TM-6710CL (LVDS).
During low, the TM-6710 series keeps integrating and, upon the rising edge of the INTEG control pulse,
outputs the frame. During integration, the signal processing keeps optical black levels as the reference
black video to clamp video levels. This has the result of cancelling out thermal noise during the
integration period.

7H

Hd

Internal Vinit

Transfer Gate
Pulse

Discharge pulse

Composite

Video

Exposure Time

5H

External

Pulse

X

min 2H

(VINIT)

1 2 3 4 5 6 7 8 9 10

VIDEO

POWER

SHUTTER

0 1

2

3

4

5

7

8

9

DWN

UP

MODE

DIGITAL

1

0 2

3

4

5

678

9

A

B

C

D

E

6

Normal mode:

F

UP

120 Hz progressive scan

200 line scan:

F

DWN

236 Hz progressive scan

100 line scan:

E

UP

300 Hz progressive scan

Advertising