Page 20 operation – JAI TM-6710 User Manual

Page 26

Advertising
background image

Page 20
Operation

TM-6710/6710CL High-Speed Progressive Scanning CCD Camera

Vref2) is between 1V and 0.2V. The controllable range of the reference top voltage (Vtop) is between
1.5V and 3V.

Examples:

“:”, “VT”, “7E”, CR

7EH = Vref top: 126

3AH, 56H, 37H, 45H, 36H, 0DH

Command W

Function: Write data to the selected pages or calibration
data table.

Saving to page (from 0 through 6):

“:”, “W”, “P” - “6”, CR
3AH, 57H, 41H - 36H, 0DH
(Page 0 is factory use only)

Saving the current gain setting to User Table (A) with the “WU” command:

“:”, “W”, “U”, “A”, CR
3AH, 57H, 55H, 41H, 0DH

Command L

Function: Select and read a memory page and set the preprogrammed data. This loads the data from the
preset page location or preset gain table.

“:”, “L”, “P” - “6”, CR
3AH, 4CH, 50H - 36H, 0DH

Command R

Function: Output data values of camera memory (PULNiX software is available).

Vtop Voltage

3

2

1

Counts

4

255

0

3

2

1

0

Vbtm 0.45V

Vtop 2.15V

A/D Input

1K (10-bit)

256 (8-bit)

V

Figure 1

Figure 2

Vref (V)

1

0.6

0.2

Counts

1.2

255

0

0.4

0.8