5troubleshooting – JAI TM-6710 User Manual

Page 35

Advertising
background image

Page 29

Troubleshooting

TM-6710/6710CL High-Speed Progressive Scanning CCD Camera

5

Troubleshooting

5.1 Problems and Solutions

Following are troubleshooting tips for common problems. Generally, problems can easily be solved by
following these instructions. If the following remedies fail to offer a solution to your problems, please
contact a PULNiX representative.

5.1.1 Symptom: No Video

Remedies: Check that the following are properly connected and operational.

•

Power supplies

•

Power cables

•

Main power source

•

Shutter control

•

Async mode

•

Lens

•

Proper level setting as Camera Link CC1 and CC2

5.1.2 Symptom: Dark Video

Remedies: Check that the following are properly connected and operational.

•

Shutter selection

•

Iris opening on the lens

•

Proper power (DC level)

5.1.3 Symptom: Non-Synchronized Video

Remedies: Check that the following are properly connected and operational.

•

Proper mode output

•

Frame grabber software camera selection

5.1.4 Symptom: RS-232 Non-Communication

Remedies: Check that the following are properly connected and operational.

•

Cable connection

•

Proper serial port selection

•

Camera has power

•

Proper Camera Link DLL selection (for TM-6710CL)

Advertising