Camera Timing Charts

TM-6710/6710CL High-Speed Progressive Scanning CCD Camera

Model: TM-6710/6710CL

Operation Mode: 120 Frames/Second

Master Clock: 50.98_HMz, M= 19.62_ nsec
Pixel Clock: 25.49_MHz, P= 39.23_ nsec

3. External Reset Timing

4. Async Reset Timing

External VD

Internal VD

FD

Digital Data

Analog Video

VINIT Trigger

Internal VD

FDV

Digital Data

Analog Video

Horizontal Frequency: 30.49_KHz
1H = 32.8_ µsec

Digital

A [254 H], (8.33 msec)

B [0 H], (6 µsec)

C [4.5 H], (147.6 µsec)

D [249.5 H], (8.18 ms)

E [254 H], (8.33 ms)

F [3 H], (98.4 µsec)

I [2 H], (65.6 µsec)

L [3 H], (49.2 µsec)

P [6 H], 98.4 µsec)

G [5 H], (0.164 ms)

J [7 H], (0.23 ms)

M [18 H], (0.295 ms)

N [3 H], (49.2 µsec)

H [249 H], (8.17 ms)

K [242 H], (7.94 ms)

0 [484 H], (7.94 ms)

S [249.5 H], (8.18 ms)

T [254 H], (8.33 ms)

Y [237 H], (7.77 ms)

CC [484 H], (7.94 ms)

Q [1 H], (32.8 µsec)

U [3 H], (98.4 µsec)

AA [18 H] (0.295 ms)

X [7 H], (0.23 ms)

BB [3 H], (49.2 µsec)

DD [6 H], (98.4 µsec)

W [0 H], (3 µsec)

Z Z [3 H], (49.2 µsec)

R [4.5 H]. (147.6 µsec)

V [5 H], (0.164 ms)

Q: Internal VD shift = 1H + async shutter speed

1H = 16.4_ µsec

Analog

Q [5 H], (0.164 ms)

H [249 H], (8.17 ms)

Z [5 H], (0.164 ms)

Q [5 H], (164 µsec)

Z [5 H], (0.164 ms)

Advertising