Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

TCGD18S41S1(H)

INDOOR COIL MODEL NO.

FC/MC/PC18

CONDENSING

ENTERING AIR

TEMPERATURE

IDCFM

450

600

750

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

65

T.C.

15.7 17.8 17.7 19.3 19.9 16.9 18.4 18.0 19.5 20.2 18.0 18.9 18.4 19.6 20.4

S.C.

16.0 13.8 12.1 12.0 9.3 17.3 15.9 13.5 13.0 9.8 18.5 17.9 14.9 13.9 10.4

KW

1.0 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9

75

T.C.

15.0 16.8 16.6 18.4 19.2 16.2 17.5 17.1 18.6 19.4 17.4 18.2 17.5 18.8 19.6

S.C.

15.3 13.6 11.7 11.6 8.9 16.6 15.6 13.2 12.8 9.6 17.9 17.6 14.7 13.9 10.3

KW

1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1

85

T.C.

14.2 15.8 15.6 17.4 18.5 15.5 16.6 16.1 17.7 18.6 16.8 17.4 16.7 18.1 18.8

S.C.

14.5 13.4 11.2 11.2 8.6 15.9 15.3 12.8 12.6 9.4 17.2 17.2 14.4 13.9 10.1

KW

1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2

95

T.C.

13.5 14.8 14.6 16.4 17.7 14.8 15.7 15.2 17.5 17.9 16.1 16.6 15.8 17.3 18.0

S.C.

13.8 13.1 10.8 10.7 8.2 15.2 15.0 12.5 12.4 9.1 16.6 16.9 14.2 14.0 10.0

KW

1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3

105

T.C.

12.6 13.7 13.2 15.1 16.5 13.8 14.6 13.8 15.5 16.7 15.0 15.5 14.4 16.0 16.8

S.C.

12.8 12.5 10.2 10.3 7.9 14.1 14.1 11.8 11.9 8.8 15.4 15.7 13.4 13.6 9.8

KW

1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5

115

T.C.

11.6 12.6 11.8 13.8 15.4 12.7 13.5 12.5 14.2 15.5 13.8 14.5 13.1 14.6 15.6

S.C.

11.9 11.9 9.6 9.8 7.6 13.1 13.2 11.2 11.6 8.6 14.3 14.6 12.7 13.3 9.6

KW

1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6

125

T.C.

10.7 11.4 10.5 12.5 14.2 11.7 12.4 11.2 12.9 14.3 12.7 13.4 11.8 13.3 14.4

S.C.

11.0 11.2 9.0 9.4 7.3 12.1 12.3 10.5 11.2 8.3 13.1 13.5 12.0 12.9 9.4

KW

1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Air Handlers

Coils

T.C.

S.C.

KW

HC18

1.00 1.00 1.00

UC18

1.00 1.00 1.00

AHP18

1.00 1.00 1.00

AHX18

1.03

1.07

0.94

AV*24

1.03

1.05

0.94

MV12B

FC/MC18B

1.02 1.03 0.89

MA08B

FC/MC18B

1.00 1.00 1.00

F4FP024

1.00 1.00 1.00

F6FP018

1.02

1.03

0.93

Furnaces

Coils

T.C.

S.C.

KW

T*(8,L)X*A12

FC/MC/PC18A

1.01

1.00

0.89

T*(8,L)X*B12

FC/MC/PC18B

1.03

1.04

0.91

T*9X*B12

FC/MC/PC18B

1.03

1.04

0.91

T*(8,L)X*A12

UC18A

1.03

1.04

0.94

T*(8,L)X*B12

UC18B

1.03

1.04

0.94

T*9X*B12

UC18B

1.03

1.04

0.94

T*(8,L)C*A12

FC/MC/PC18A

1.03 1.04 0.91

T*(8,L)C*B12

FC/MC/PC18B

1.01 1.02 0.89

(T*9C/T*9V)*B12 FC/MC/PC18B

1.02 1.05 0.89

T*(8,L)C*A12

HC18

1.02 1.05 0.90

T*(8,L)C*A12

UC18A

1.03 1.05 0.91

T*(8,L)C*B12

UC18B

1.02 1.03 0.89

(T*9C/T*9V)*B12 UC18B

1.03 1.05 0.89