Johnson Controls Unitary Products

All dimensions are in inches. They are subject to change with-
out notice. Certified dimensions will be provided upon request.

Physical and Electrical Data

MODEL

TCGD18

S41S1(H)

TCGD24

S41S1

TCGD30

S41S1(H)

TCGD36

S41S1(H)

TCGD42

S41S1(H)

TCGD48

S41S1(H)

TCGD60

S41S1

Unit Supply Voltage

208-230V, 1

 60Hz

Normal Voltage Range

1

187 to 252

Minimum

Circuit

Ampacity

9.8 12.4 14.7 17.9 21.5

21.1 34.3

Max. Overcurrent Device Amps

2

15 20 25 30 35 35 60

Min. Overcurrent Device Amps

3

15 15 15 20 25 25 35

Compressor Type

Rotary

Recip

Recip

Recip

Recip

Recip

Scroll

Compressor Amps

Rated

Load

7.4

9.3 10.6 13.1 16.0 15.7 26.2

Locked

Rotor

40.0 43.0 54.0 74 84 84 150

Crankcase

Heater

No No No No No No No

Fan

Motor

Amps

Rated

Load

0.5 0.8 1.4 1.5 1.5 1.5 1.5

Fan

Diameter

Inches

17.5

17.5

17.5 22 22 22 24

Fan Motor

Rated

HP

1/12 1/8 1/4 1/4 1/4 1/4 1/4

Nominal

RPM

1100

1075

1100 850 850 850 850

Nominal

CFM

1400 1950 2050 3200 2950 2950 3600

Coil

Face Area Sq. Ft.

9.60

9.60

9.60

13.07

14.16

14.16

18.68

Rows

Deep

1 1 1 1 1 1 1

Fin

/

Inches

23 23 23 23 23 23 23

Liquid Line Set OD (Field Installed)

3/8

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line Set OD (Field Installed)

5/8

3/4

3/4

3/4

7/8

7/8

7/8

Unit Charge (Lbs. - Oz.)

4

3 - 3

3 - 13

3 - 14

4 - 9

4 - 5

4 - 9

5 - 6

Charge

Per

Foot,

Oz.

0.58 0.62 0.62 0.62 0.67 0.67 0.67

Operating Weight Lbs.

97

129

131

145

173

173

195

Models with “H” on the end of the model number have a factory installed start kits.

1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or sub-

tract the amount of refrigerant, using the difference in length multiplied by the per foot value.

B

C

A

Unit

Model

Dimensions

(Inches)

Refrigerant Connection

Service Valve Size

A

1

1. Including Fan Guard.

B

C

Liquid

Vapor

18

28

23-1/2

23-1/2

3/8”

3/4”

24

28

23-1/2

23-1/2

30

28

23-1/2

23-1/2

36

28

29

29

42

30

29

29

7/8”

48

30

29

29

60

32

33-5/8

33-5/8