Johnson Controls TCGD18 THRU 60 User Manual

Page 5

Advertising
background image

359319-BTG-G-0509

Johnson Controls Unitary Products

5

— = Not applicable.

13 SEER AC WITH AHP / SHP / AHX / F*FP

TCGD18S41S1(H)

AHP18 17

–

650

17.5

12.9

13.00

11.00

AHX18

17

-

630

18.0

13.8

14.50

12.00

F4FP024 18

–

600 17.5 12.9

13.00

11.00

F6FP018

17

-

600

17.8

13.3

14.50

12.00

TCGD24S41S1(H)

AHP30 17

–

795

24.0

16.8

13.00

11.00

AHX30

17

–

820

24.0

16.9

14.50

12.00

AHX36

21

–

815

24.0

16.9

14.50

12.00

F4FP036

21.5

–

800

24.0

16.7

13.00

11.00

F6FP030

17

–

850

24.0

16.8

14.00

11.80

F6FP036

21

–

855

24.0

17.0

14.00

12.00

TCGD30S41S1(H)

AHP30 17

–

1015

29.0

21.0

13.00

11.00

AHP36 21

–

1040

29.0

21.0

13.00

11.00

AHX30

17

–

1025

29.4

22.2

14.00

11.75

AHX36

21

–

1005

30.0

22.3

14.50

12.00

F4FP040 18

–

1050 29.0 21.0

13.00

11.00

F6FP030

17

–

1035

29.2

21.6

13.50

11.40

F6FP036

21

–

980

29.4

21.4

14.00

12.00

TCGD36S41S1(H)

AHP36 21

–

1235

35.0

24.8

13.00

11.00

AHP42 21

–

1255

35.0

24.8

13.00

11.00

AHX36

21

–

1225

35.2

25.0

13.50

11.50

AHX42

21

–

1190

35.4

25.2

14.00

11.80

F5FP048 24

–

1235 35.0 24.8

13.00

11.00

F6FP042

21

–

1290

35.8

25.8

13.50

11.50

TCGD42S41S1(H)

AHP42 21

–

1485

41.0

29.2

13.00

11.00

AHX42

21

–

1395

42.0

29.9

14.50

12.00

F5FP048 24

–

1455 41.0 29.2

13.00

11.00

F6FP042

21

–

1455

42.0

30.1

14.00

11.75

F6FP048

24

–

1380

41.5

29.4

13.50

11.70

TCGD48S41S1(H)

AHP/SHP48 24

–

1675 48.0 34.4 13.00 11.00

AHP/SHP60 24

–

1600 48.0 35.0 13.50 11.00

AHX48

24

–

1660

48.0

35.4

13.50

11.50

F5FP048 24

–

1600 48.0 34.4

13.00

11.00

F5FP060 24

–

1600 48.0 34.4

13.00

11.00

F6FP048

24

–

1625

47.0

34.8

13.00

11.30

TCGD60S41S1

AHP/SHP60 24

–

1850 57.0 38.5 13.00 11.00

AHX60

24

–

1905

58.5

40.0

13.50

11.50

F5FP060 24

–

1900 57.0 38.5

13.00

11.00

F6FP060

24

–

1710

57.5

39.0

13.50

11.50

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8

°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.

1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

MODEL

AIR HANDLER

COIL

MODEL

1

COOLING

MODEL

W

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.

Advertising