2 rear panel 2 controls, connectors and displays – JVC BR-DV600U User Manual

Page 6

Advertising
background image

8

2-2 Rear Panel

2 CONTROLS, CONNECTORS AND DISPLAYS

DC 12V

PGZ01945

TIMER

TIME CODE

SPARE

COMPONENT

VIDEO

SYNC IN

REC

OFF

PLAY

DV

IN/OUT

REMOTE

AUDIO

2

1

SERIAL

CH 1/3

OUT

OUT

IN

IN

B-Y

IN

Y/C

LINE

OUT

OUT

MONITOR

CH 2/4

MONITOR

OUT

R-Y

Y

1

2

7

8

6

0

!

9

5

4

3

#

@

$

%

^

&

( )

*

0

[VIDEO MONITOR OUT] connector
Connect a video monitor to check the output video or
on-screen display from this unit.

!

[Y/C OUT] connector
Outputs Y/C signals.

@

[LINE OUT] connector
Outputs composite signals.

# [Y/C IN]

connector

Receives Y/C signals.

$

[LINE IN] connector
Receives composite signals.

%

[DV IN/OUT] connector
Outputs or receives IEEE 1394 standard digital signals.
In addition to digital video and audio signals, control
signals can be input or output to/from a personal
computer provided with the DV connector (i.LINK), etc.

^

[COMPONENT IN] connectors
Receive component signals.
The signal level is for Betacam specifications.

&

[COMPONENT OUT] connectors
Output component signals.
The signal level is for Betacam specifications.

*

[AUDIO IN] connectors
Receives audio signals (analog).

(

[AUDIO OUT] connectors
Outputs audio signals (analog).The output audio
channel can be selected with the

8 [AUDIO OUTPUT]

switch on the front panel.

See “Audio system connections” on page 12.

)

[AUDIO MONITOR OUT] connector
Connect to the audio input of a TV monitor or audio
system. The audio channel to be monitored can be
selected with the

9 [AUDIO MONITOR OUT] switch.

1

AC socket
Connect the provided power cable to supply AC 120 V
(U MODEL), AC 220 – 240 V (E MODEL).

This unit can be activated automatically when power is
supplied according to the setting of

7 [TIMER] switch.

See “EXTERNAL TIMER-START FUNCTION” on

page 26.

2

DC socket
Connect DC 12 V (XLR 4-pin).

This unit can be activated automatically when power is
supplied according to the setting of

7 [TIMER] switch.

See “EXTERNAL TIMER-START FUNCTION” on

page 26.

3

[REMOTE] connector (JVC bus)
This unit can be controlled by the RM-G800 via this
connector.

4

[REMOTE] connector (RS-422 Serial Connector)
This unit can be controlled by an RS-422 controller.
This can be changed to an RS-232C interface if re-
quired. For details, contact your local JVC service
center.

5

[REMOTE] connector (SERIAL)
Connect a wired remote control such as the RM-G30 to
control this unit.

6

[SPARE] connector
This connector is empty and has no function.

7

[TIMER] switch
Use to select the timer operation.
REC : Timer recording
OFF : Timer function OFF
PLAY : Timer playback

See “EXTERNAL TIMER-START FUNCTION” on

page 26.

8

[TIME CODE OUT] connector
Use to output time code signals.

9

[SYNC IN] connector
Input reference sync signals.

See “Reference sync signal” on page 11.

9

2-3 On-Screen Display

2 CONTROLS, CONNECTORS AND DISPLAYS

Five types of indication are available.

2. Menu switch

This indication is used to set the menu switch.

Shown when the [MENU] button is pressed.

Press it once again to restore the previous display.

See “MENU SWITCHES” on page 17.

3. Hour meter

Shows the rotating head usage time.
Select “HM: HOUR METER” on the menu switch’s group
select screen.

4. Tape remaining time

Shows the tape remaining time.
Shown when the No. 505 <REMAIN ENABLE> menu
switch is set to “ON”.

5. Warning message

Automatically shown when an abnormality occurs.

See “Warning indicators” on page 40.

The on-screen display can be viewed on a monitor connected to the rear panel’s [VIDEO MONITOR OUT] connector when the
No. 500 <ON SCREEN> menu switch is set to “ON”. Pressing the [MENU] button will bring up the menu switch display regard-
less of this setting.

Mode

Time display

Counter mode

Tape counter

Counter mode indication

Time display contents

CTL

CTL counter data

TCR

Time code reader data

TCG

Time code generator data

UBR

User bits reader data

UBG

User bits generator data

TIME

Time

DATE

Date

1. Tape counter
The type of data shown on the tape counter display is set

with the [COUNTER] switch and menu switch.

Related settings
[COUNTER] switch (front panel)
No. 504 <INFORMATION SELECT>
No. 514 <TIME DISPLAY SELECT>

Mode:

Shown when the No. 504 <INFORMA-
TION SELECT> menu switch is set to
“MODE + TIME”. In this case, the unit’s
operation status can be checked on the
monitor screen.

Time display: The indications shown in the table on the

left are available with the counter mode
indication.

Menu switch

Hour meter

Tape remaining time

Warning code

(In case of condensation)

STOP

TCR 1 2 : 0 0 : 0 0 : 0 0

0 0 ~

~

:

SYSTEM

0 0 ~

~

:

T I ME CODE

0 0 ~

~

: ONSCREEN

M

:

HOUR METER

3
4
5
H

0 0 ~

~

:

AUD I O

2

0 0 ~

~

:

SERVO / SYSTEM

0

0 0 ~

~

:

V I DEO

1

( HOUR METER )

H

: DRUM HOUR METER

0 0 0 0 0

D

0H

TCR

0 0 :

1 2 :

0 0 : 0 0

0 1 : 0 0

WARN I NG 0 2 0 1

CONDENSAT I ON ON DRUM

Minute

Hour

Advertising