T E S T I N G G R O U N D FA U LT C I R C U I T

INTERRUPTER (GFCI)

CAUTION: Ground Fault Circuit Interrupter (GFCI)

MUST be tested before each use of the washer.
If the results in each one of the following steps are

not as described, shut washer off immediately. DO

NOT operate until the washer has been inspected

by a qualified electrician or your dealer.

1. Plug GFCI into grounded receptacle. Connect high

pressure outlet hose and turn on water supply.

2. Press and release “RESET” button (A) to verify power

to the washer.

3. Press “TEST” button (B). Red indicator bar (C) on reset

button should appear. (Power to the washer should be

interrupted).

4. Press and release the “RESET” button. Power should

be restored to the washer.

NOTE: GFCI test instruction are also found on the front of

the GFCI.

Preparing the Washer

A

A

C

B

B

C