Service – John Deere HR1250E1 User Manual

Page 28

Advertising
background image

28

Operator’s Manual

T E S T I N G G R O U N D FA U LT C I R C U I T

INTERRUPTER (GFCI)

CAUTION: Ground Fault Circuit Interrupter (GFCI)

MUST be tested before each use of the washer.
If the results in each one of the following steps is

not as described, shut washer off immediately. DO

NOT operate until the washer has been inspected

by a qualified electrician or your dealer.

1. Plug GFCI into grounded receptacle. Connect high

pressure outlet hose and turn on water supply.

2. Press and release “RESET” button (A) to verify power

to the washer.

3. Press “TEST” button (B). Red indicator bar (C) on reset

button should appear. (Power to the washer should be

interrupted.)

4. Press and release the “RESET” button. Power should

be restored to the washer.

NOTE: GFCI test instructions are also found on the front

of the GFCI.

CLEANING INLET WATER

CAUTION: Disconnect power cord from electrical

receptacle before cleaning inlet screen.

IMPORTANT: Do not operate washer with water inlet

screen removed. Foreign material may

enter and damage pump or valves.

Inspect the water inlet screen (A) (inside brass fitting)

periodically for buildup of scale, grit and dirt. Clean as

necessary. If it is corroded or broken, replace.

Service

CLEANING DETERGENT HOSE STRAINER

Check detergent hose strainer for detergent or contaminant

buildup.

Remove strainer from hose and back flush with clean water

and a stiff bristle brush.

NOTE: If strainer frequently becomes plugged, check

detergent to be sure it is thoroughly mixed.

A

A

A

C

B

B

C

Advertising