CLEANING OR REPLACING ADJUSTABLE

FAN SHUTTERS

CAUTION: To avoid injury from high pressure

spray, nozzle wand MUST be disconnected from

gun before servicing.
CAUTION: Fan shutter metal edges are extremely

sharp. Wear gloves.

1. Slide nozzle collar rearward.
2. Gently pry tabs (B) open and remove nozzle end (A).
3. Clean regulator and fan shutter assembly (C).
4. Squeeze nozzle end tabs inward, and slide nozzle end

back over nozzle assembly.

CLEANING OR REPLACING NOZZLE

ORIFICE

CAUTION: To avoid injury from high pressure

spray, nozzle wand MUST be disconnected from

gun before servicing.

1. Rotate nozzle collar (A) to open shutter.
2. Insert cleaning tool (B) (provided) into orifice and turn.
3. Flush nozzle wand with water.
4. If nozzle can not be cleaned thoroughly, insert a

2.0 mm hex wrench (C) (provided) into orifice, turn

counterclockwise and remove orifice.

5. Check orifice for wear or damage; clean or replace if

necessary.