ROUGHING-IN REFERENCE

(RECTANGULAR)

AMIGA™, Left Hand

*72''

18''

36''

2''

16'' x 4''

14''

12" H x 18" L

Service Access

11-1/8''

Motor

Opt. Service Access

10

Jacuzzi Whirlpool Bath K272000AF 7/06

*72''

18''

36''

2''

16'' x 4''

14''

Motor

12" H x 18" L

Service Access

Opt. Service Access

11-1/8''

AMIGA™, Right Hand

14-1/2"

AMIGA WITH INTEGRAL SKIRT,

Left Hand

*72''

36''

2''

16'' x 4''

11-1/8''

Motor

17-3/8"

*72''

36''

2''

16'' x 4''

14-1/2''

Motor

11-1/8''

AMIGA WITH INTEGRAL SKIRT,

Right Hand

17-3/8''

BIANCA™

*72"

24"

48"

8-1/2"

13-3/4"

13-1/2" x 4"

(Left-hand only as shown)

2"

Motor

12" H x 18" L

Service Access

Opt. Service Access

*60"

32"

CETRA™ W/INTEGRAL SKIRT, Left Hand

15-5/8"

2"

10" x 4"

9-3/8"

5-11/16"

Motor

CETRA™ W/INTEGRAL SKIRT, Right Hand

*60"

32"

15-5/8"

2"

10" x 4"

9-3/8"

5-11/16"

Motor

9"

CETRA™ 532, Left Hand

*60"

32"

16"

12" x 4"

Motor

2"

5-3/4"

12" H x 18" L

Service Access

Opt. Service Access

9"

CETRA™ 532, Right Hand

12" x 4"

Motor

2"

5-3/4"

12" H x 18" L

Service Access

Opt. Service Access

*60"

32"

16"

9"
CETRA™ 536, Left Hand

*60"

36"

18"

12" x 4"

Motor

12" H x 18" L

Service Access

Opt. Service Access

2"

5-3/4"

9"

CETRA™ 536, Right Hand

12" x 4"

Motor

12" H x 18" L

Service Access

Opt. Service Access

2"

5-3/4"

*60"

36"

18"

9"

CETRA™ 536 WITH INTEGRAL SKIRT, Left Hand

*60"

36"

17-3/8"

12" x 4"

2"

5-3/4"

Motor

9"

CETRA™ 536 WITH INTEGRAL SKIRT, Right Hand

12" x 4"

2"

5-3/4"

Motor

*60"

36"

17-3/8"

2-1/2"

*60"

16"

32"

12" x 5"

8-1/4"

LUXURA™ 5, Left Hand

Motor

12" H x 18" L

Service Access

Opt. Service Access

2-1/2"

5-1/4"

LUXURA™ 5, Right Hand

2-1/2"

15" x 5"

8-1/4"

Motor

12" H x 18" L

Service Access

Opt. Service Access

2-1/2"

5-1/4"

*60"

16"

32"

ROUGHING-IN

*Add 1/4" (6,4 mm) to this dimension when roughing-in for 3-wall niche.
NOTE: 1. The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm).

2. Service Access dimensions given are minimum. Service access is still required for units that do not have pre-installed Pump/Motor.
3. Measurements inside each unit represent cutout in floor to allow for drain/overflow.
4. All measurements are in inches. To convert to millimeters, multiply inches by 25.4.
5. Not all export units come with pre-installed Pump/Motor.

Advertising