How to Use the External Control

7About the External Control

The Monitor has the MAKE/TRIGGER terminal, which allows you to control the monitor by the MAKE (make
contact) or TRIG. (trigger) system selected in the function setting.

MAKE (make contact) system:

Controls the function by short-circuiting the corresponding pin terminal to the
GND pin terminal, or disconnecting (opening) it.

TRIG. (trigger) system:

Controls the function by inputting the pulse signal instantaneously to the
corresponding pin terminal.

* Select “MAKE” or “TRIG.” from “REMOTE SYSTEM” in SET-UP MENU.

☞ “REMOTE SYSTEM” on page 14

NOTES:
• The external control has priority over operations using front panel buttons or menu functions of the monitor.
• When using the make contact system, you cannot use the functions which are applied to the MAKE/TRIGGER terminal

operating the front panel buttons or the menu of the monitor. (When using the trigger system you can also use those
functions operating the monitor directly.)

7How to Use the MAKE/TRIGGER Terminal

7 Function of the MAKE/TRIGGER terminal
The following are the configurations and the functions
of the pin terminals of the RJ-45 connector. You can
change the functions applied to the 1st to 6th pin
terminals by setting “REMOTE SYSTEM” of SET-UP
MENU.

Caution:
This is a female
connecter.

7 To change the functions applied to the pin

terminals

1. Display SET-UP MENU, then move the MENU

control to / to select “REMOTE SYSTEM,” then
move it to

.

2. Move the MENU control to / to select

“CONTROL FORM,” then move it to

/

to select

“SET.”

3. Move the MENU control to / to select the

number of the pin terminal (PORT F1 – PORT F6)
you want to set, then move it to

/

to select the

function.

NOTE:
• You cannot apply two or more functions to one terminal.

NO.

1

2

3

4

5

6

7

8

INP. A

INP. C

MARKER

ASPECT

TALLY

L. METER

Functions to be controlled

Changes the input to INPUT A

Changes the input to INPUT C

Turns on/off MARKER

Changes ASPECT

Controls the tally lamp

Turns on/off AUDIO LEVEL
METER

External control

GND