Library Complex

96154 • Revision K

Chapter 1 Introduction 19

■

The system PDU, connected directly to the branch circuit, provides AC power to

three DC power grids and the electronics control module.

■

The N+1 PDU supplies added +48 VDC load sharing power to each of the three DC

power grids and an extra AC-to-DC power supply for the electronics control

module.

The base power configuration provides power to the:

■

Tape drive power supplies

■

Robotic rail power supplies

■

Customer Interface Module power supplies

■

Touch screen operator control panel

■

Electronics control module power supplies

Note –

The base power configuration does not offer redundant AC power.

2N Power Configuration

The 2N power configuration contains the base power configuration (PDU 1) and a

second PDU, PDU number 2.

This configuration provides power to the same components as N+1, plus power for:

■

Optional, redundant load sharing power supplies

■

Two additional accessory racks for customer components

■

Redundant controller cards

Note –

The 2N PDU is required for the 2N drive power, 2N robotic power, and also for

the additional rack installed.

Library Complex

A library complex is created by connecting two or more SL8500 libraries together with

Pass-thru Ports (PTPs).

The maximum size library complex possible consists of either:

■

32 libraries for Host Software Component (HSC) systems, connected through PTPs,

containing over 320,000 cartridge slots and 2,048 tape drives.

■

31 libraries for Automated Cartridge System Library Software (ACSLS) connection,

connected through PTPs, containing over 320,000 cartridge slots and 1,984 tape

drives.

Note –

A library complex with functional pass-thru ports (PTPs) cannot be partitioned.

All PTPs must be disabled before partitioning can be enabled. See

“Library

Partitioning” on page 22

for details.