CHARCOAL FILTER

Charcoal Filter, Sharp part number RK-240 which was
installed in your oven, is used for nonvented, recircu-
lated installation. The filter should be changed every
6 to 12 months depending on use. See page 14 for
ordering information.

1. Disconnect power to the oven at the circuit breaker

panel or by unplugging.

2. Remove the three louver mounting screws and

push down carefully on the tab at each end of the
louver to disengage it. (See illustration.)

3. Pull the louver away from the unit.

4. Change the charcoal filter.

5. Carefully push the louver back into place (engaging

both the bottom and top tabs) and replace the
screws removed in step 2.

Light cover

Screw

Light bulbs

R E P L A C I N G P A R T S

LIGHT BULBS

1. To replace light bulbs, first disconnect power to the

oven at the circuit breaker panel or by unplugging.

2. To release cover, remove the screw on the light cover.

(See illustration.)

3. Replace light bulbs with equivalent watt bulb

available from your Sharp Authorized Servicer or
parts distributor. Bulbs are also available at most
hardware stores or lighting centers. DO NOT USE
A BULB LARGER THAN 30 WATTS.

4. Close light cover and secure with screw removed in

step 2.

CAUTION: Light cover may become very hot. Do not

touch glass when light is on.

Louver

Charcoal filter

(white side faces front)

Top tab

Bottom tab

Screw

Screw

Screw

1.1 R-1510/11/12/14#349

4/1/03, 11:39 AM